CG5600LTR Allicdata Electronics
Allicdata Part #:

CG5600LTR-ND

Manufacturer Part#:

CG5600LTR

Price: $ 0.92
Product Category:

Circuit Protection

Manufacturer: Littelfuse Inc.
Short Description: GDT 600V 5KA THROUGH HOLE
More Detail: Gas Discharge Tube 600V 5000A (5kA) 2 Pole Throug...
DataSheet: CG5600LTR datasheetCG5600LTR Datasheet/PDF
Quantity: 1000
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
1000 +: $ 0.83222
Stock 1000Can Ship Immediately
$ 0.92
Specifications
Series: CG5
Packaging: Tape & Reel (TR) 
Lead Free Status / RoHS Status: --
Part Status: Active
Moisture Sensitivity Level (MSL): --
Voltage - DC Spark Over (Nom): 600V
Impulse Discharge Current (8/20µs): 5000A (5kA)
Tolerance: --
Number of Poles: 2
Fail Short: No
Mounting Type: Through Hole
Package / Case: Axial Cylinder
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Gas Discharge Tube Arresters (GDT) are commonly used electrical safety devices that protect circuits from the harmful effects of transient overvoltage caused by lightning or other extreme disturbances. An example of this type of arrester is the CG5600LTR. It is capable of providing a high level of protection against surge and induced voltage with its remarkable response time of less than 1.4μs.

The CG5600LTR is designed for medium-voltage and high-voltage overhead distribution networks, and is used primarily for Lightning Protection Zone (LPZ) 0 and LPZ1 outside. This device is intended for applications in which no current discharges, except when fault current flows in the arrestor. It incorporates a non-linear voltage limiter as well as a spark gap arrestor, which is used to divert the majority of fault current away from the power source.

In terms of its operation, the CG5600LTR is designed to provide a high degree of surge protection. The arrester works by effectively grounding transient currents with its spacer gap or spark gap. The spark gap also works to quench any arc while also dissipating the associated energy. This process helps to reduce fault currents and other accompanying surges. The spark gap reduces the voltage to a safe value and also affords additional margin for the lightning arrester to intercept the surge.

The CG5600LTR also incorporates a gas-filled nonlinear resistor element, which is the true active part of the arrester. This element is designed to protect the system against fault currents during surge protection. The voltage limiting element works by limiting the amount of current that can flow through it to a safe level. The limiting resistor element can be made up of either semiconductor or ceramic materials.

Once the fault current reaches a certain level, the CG5600LTR\'s spark gap will be activated, which is then followed by the arrester\'s main function--limiting the voltage on the line. The combination of the spark gap and the voltage limiting element ensures that any transient voltages are immediately discharged and removed from the power system. This ensures that no damage is done to the equipment.

The CG5600LTR gas discharge tube arrester also incorporates a variety of features that are designed to reduce the risk of equipment failure due to lightning strikes or surges. These features include protection against overvoltage, overcurrent and electromagnetic interference. The arrester also includes a range of accessories that allow it to be easily installed, including mounting hardware, connective accessories, insulation cords and grounding terminals.

In summary, the CG5600LTR gas discharge tube arrester is an excellent device that offers effective protection against transient overvoltage, overcurrent and electromagnetic interference. It offers a fast response time and is designed with a number of features that ensure maximum safety for the power system. The CG5600LTR\'s spark gap helps to dissipate the energy from any arcing, while its voltage limiting element helps to protect against any excess surge currents. Accessories, such as mounting hardware, insulation cords and grounding terminals, allow for easy installation and maximum protection.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "CG56" Included word is 7
Part Number Manufacturer Price Quantity Description
CG562U150X3L Cornell Dubi... 27.75 $ 1000 CAP ALUM 5600UF 150V SCRE...
CG5600 Littelfuse I... 0.7 $ 1000 GDT 600V 5KAGas Discharge...
CG5600L Littelfuse I... 0.74 $ 1000 GDT 600V 5KA THROUGH HOLE...
CG5600LS Littelfuse I... 0.83 $ 1000 GDT 600V 5KA SURFACE MOUN...
CG5600L-02 Littelfuse I... 0.85 $ 1000 GDT 600V 5KA THROUGH HOLE...
CG5600LTR Littelfuse I... 0.92 $ 1000 GDT 600V 5KA THROUGH HOLE...
CG5600MS Littelfuse I... 0.98 $ 1000 GDT 600V 5KA SURFACE MOUN...
Latest Products
B88069X9960B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9960B102 Allicdata Electronics
B88069X9630C152

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9630C152 Allicdata Electronics
B88069X8591B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8591B102 Allicdata Electronics
B88069X8291S102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8291S102 Allicdata Electronics
B88069X7831B502

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X7831B502 Allicdata Electronics
B88069X5131B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X5131B102 Allicdata Electronics