Allicdata Part #: | CR4810-50-ND |
Manufacturer Part#: |
CR4810-50 |
Price: | $ 86.13 |
Product Category: | Industrial Controls |
Manufacturer: | CR Magnetics Inc. |
Short Description: | TRANSDCR VLTAGE 0-50VAC AVRG RMS |
More Detail: | N/A |
DataSheet: | CR4810-50 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 78.29640 |
Series: | CR4800 |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Type: | Average RMS AC Voltage Transducer |
Moisture Sensitivity Level (MSL): | -- |
Input Range: | 0 ~ 50VAC |
Output: | 0 ~ 5VDC |
Response Time: | 250ms |
Accuracy: | 0.5% |
Voltage - Supply: | 24VDC |
Mounting Type: | DIN Rail |
Termination Style: | Screw Terminal |
Operating Temperature: | 0°C ~ 60°C |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
CR4810-50 is a type of Monitor-Current/Voltage Transducer which are used to measure electrical current and voltages. It provides analog output proportional to the input current or voltage, which makes it ideal for a variety of applications.
CR4810-50 operates on a differential-input principle which is quite different from series-input transducers. Unlike other transducers, it features a completely enclosed design, making it suitable for use in harsh environments. It also features a low-voltage and low-impedance design, making it easy to integrate into most applications.
The primary application of CR4810-50 transducer is in the industrial environment, such as in factories, automotive plants, power plants, and other facilities. It can also be used in the medical and telecommunications industries. It can be used to monitor current and voltage levels in these environments and to provide continuous feedback about the functioning of the system.
The working principle of the CR4810-50 is based on two important principles: the current/voltage transducer principle and the thrust transducer principle. The former is used for measuring the electric current flowing into a circuit and the latter is used for measuring the electric voltage across a circuit.
The current flowing into a circuit is measured by the transducer which is connected to the circuit through a conductor, usually an insulated wire. The current flowing into the conductor then is detected by an electronic device, usually an amplifier circuit. The amplified signal is then sent to a digital processor, usually a microcontroller. The processor converts the signal to an analog output proportional to the input current.
On the other hand, the voltage in the circuit is measured by the thrust transducer principle. This principle employs two elements – a conductor and a metal thrust housing. The conductor has an electrical field strength which is applied to the thrust housing when the conductor moves in the thrust housing. The electrical field causes a displacement of the thrust housing. The displacement in turn is converted into an analog output proportional to the voltage across the conductor.
CR4810-50 is a very reliable and robust transducer which is suitable in many different applications. It is easy to integrate into an existing system due to its low-voltage and low-impedance design. It can also be used in a variety of environments, making it suitable for industrial, medical, and telecommunications use.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
CR4810-250 | CR Magnetics... | 86.13 $ | 1000 | MODULE AC VOLT TRANSMITTR... |
CR4810-150 | CR Magnetics... | 86.13 $ | 1000 | TRANSDCR VLTAGE 0-50VAC A... |
CR4810-500 | CR Magnetics... | 86.13 $ | 1000 | TRANSDCR VLTGE 0-500VAC A... |
CR4810-50 | CR Magnetics... | 86.13 $ | 1000 | TRANSDCR VLTAGE 0-50VAC A... |
CR4820-150 | CR Magnetics... | 92.74 $ | 1000 | TRANSDCR VLTGE 0-150VAC A... |
CR4820-250 | CR Magnetics... | 92.74 $ | 1000 | TRANSDCR VLTGE 0-250VAC A... |
CR4820-50 | CR Magnetics... | 92.74 $ | 1000 | TRANSDCR VLTAGE 0-50VAC A... |
CR4820-500 | CR Magnetics... | 92.74 $ | 1000 | TRANSDCR VLTGE 0-500VAC A... |
CR4850-500 | CR Magnetics... | 98.95 $ | 1000 | TRANSDCR VLTGE 0-500VAC A... |
CR4850-50 | CR Magnetics... | 98.95 $ | 1000 | TRANSDCR VLTAGE 0-50VAC A... |
CR4850-250 | CR Magnetics... | 98.95 $ | 1000 | TRANSDCR VLTGE 0-250VAC A... |
CR4850-150 | CR Magnetics... | 98.95 $ | 1000 | TRANSDCR VLTGE 0-150VAC A... |
CR4820-20 | CR Magnetics... | 105.43 $ | 1000 | MODULE AC VOLT TRANSMITTR... |
CR4820-600 | CR Magnetics... | 105.43 $ | 1000 | VOLTAGE TRANSDUCER 600V 5... |
CR4860-500 | CR Magnetics... | 112.5 $ | 997 | TRANSDCR VLTGE 0-500VAC A... |
CR4860-50 | CR Magnetics... | 112.5 $ | 1000 | TRANSDCR VLTAGE 0-50VAC A... |
CR4860-150 | CR Magnetics... | 112.5 $ | 1000 | TRANSDCR VLTGE 0-150VAC A... |
CR4860-250 | CR Magnetics... | 112.5 $ | 1000 | TRANSDCR VLTGE 0-250VAC A... |
CR4880-150 | CR Magnetics... | 128.87 $ | 1000 | TRANSDCR VLTGE 0-150VAC A... |
CR4880-250 | CR Magnetics... | 128.87 $ | 1000 | TRANSDCR VLTGE 0-250VAC A... |
CR4880-50 | CR Magnetics... | 128.87 $ | 1000 | TRANSDCR VLTAGE 0-50VAC A... |
CR4880-500 | CR Magnetics... | 128.87 $ | 1000 | TRANSDCR VLTGE 0-500VAC A... |
CR4870-500 | CR Magnetics... | 137.38 $ | 1000 | TRANSDCR VLTGE 0-500VAC A... |
CR4870-50 | CR Magnetics... | 137.38 $ | 1000 | TRANSDCR VLTAGE 0-50VAC A... |
CR4870-250 | CR Magnetics... | 137.38 $ | 1000 | TRANSDCR VLTGE 0-250VAC A... |
CR4870-150 | CR Magnetics... | 137.38 $ | 1000 | TRANSDCR VLTGE 0-150VAC A... |
CR4802AA | Littelfuse I... | 0.0 $ | 1000 | TVS DIODE 220V TO220 |
CR4802AB | Littelfuse I... | 0.0 $ | 1000 | TVS DIODE 220V TO220 |
CR4802AC | Littelfuse I... | 0.0 $ | 1000 | TVS DIODE 220V TO220 |
CR48-1-1 | Essentra Com... | 0.39 $ | 1000 | RIVET BLIND 0.315" NYLON ... |
CR48-2-1 | Essentra Com... | 0.4 $ | 1000 | RIVET BLIND 0.441" NYLON ... |
CR48-3-1 | Essentra Com... | 0.41 $ | 1000 | RIVET BLIND 0.567" NYLON ... |
MFP 3/64"CR48"BX | 3M | 0.0 $ | 1000 | HTSHRNK MFP 3/64"X4'(1')C... |
MFP 1/16"CR48"BX | 3M | 0.0 $ | 1000 | HTSHRNK MFP 1/16"X4'(1')C... |
MFP 3/32"CR48"BX | 3M | 0.0 $ | 1000 | HTSHRNK MFP 3/32"X4'(1')C... |
MFP 1/8"CR48"BX | 3M | 0.0 $ | 1000 | HTSHRNK MFP 1/8"X4'(1')CL... |
MFP 3/16"CR48"BX | 3M | 0.0 $ | 1000 | HTSHRNK MFP 3/16"X4'(1')C... |
MFP 1/4"CR48"BX | 3M | 0.0 $ | 1000 | HTSHRNK MFP 1/4"X4'(1')CL... |
MFP 3/8"CR48"BX | 3M | 0.0 $ | 1000 | HTSHRNK MFP 3/8"X4'(1')CL... |
MFP 1/2"CR48"BX | 3M | 0.0 $ | 1000 | HTSHRNK MFP 1/2"X4'(1')CL... |
VOLT DIVIDER 3KV IN 200MV OUT
VOLT DIVIDER 5KV IN 200MV OUT
SIGNAL CONVERTER/DISCONNECTOR
TRANSDUCER MEASURING
TRANSDUCR AC VOLT 5V-OUT 500V-IN
VOLT DIVIDER 2KV IN 200MV OUT