Allicdata Part #: | DRTH24A06R-ND |
Manufacturer Part#: |
DRTH24A06R |
Price: | $ 36.97 |
Product Category: | Industrial Controls |
Manufacturer: | Sensata-Crydom |
Short Description: | RELAY TIME DELAY 6A 280V DIN |
More Detail: | Interval Time Delay Relay SPST-NO (1 Form A) 6A @ ... |
DataSheet: | ![]() |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
10 +: | $ 33.61050 |
Series: | DRT |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Relay Type: | Solid State Relay |
Moisture Sensitivity Level (MSL): | -- |
Function: | Interval |
Circuit: | SPST-NO (1 Form A) |
Delay Time: | -- |
Contact Rating @ Voltage: | 6A @ 280VAC |
Voltage - Supply: | 180 ~ 240VAC/DC |
Mounting Type: | DIN Rail |
Termination Style: | Screw Terminal |
Timing Adjustment Method: | Screwdriver Slot |
Timing Initiate Method: | Input Voltage |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Time Delay Relays are electromechanical devices used for the control of electrical circuits and for the performance of switching operations. The purpose of Time Delay Relays is to achieve a preset delay in order to provide a timed control of the circuit. The DRTH24A06R is an example of these devices, specifically an electronic time delay relay that is used in a variety of applications.
The DRTH24A06R is a compact, 24Vdc relay module equipped with a delay timer. It is designed for use in industrial automation and process control systems, and for the design of automatic control circuits. The relay module features an 8-pin DIN connector, a LED for power and timer indication, and a pair of output relays. The relays are designed for switching both AC and DC voltages up to 500V. The maximum switching current is 10A.
The time delay range of the DRTH24A06R can be set between 0.1 second to 100h. The timer can be controlled manually through the three control knobs installed on the relay module. The time setting can also be adjusted by the user through the TTL compatible signal interface of the relay module. The interface has 3 inputs, RESET, START and STOP, and these can be activated by external signals.
The working principle of the DRTH24A06R is based on the mechanism of a relay. When an electric current passes through the two coils of the relay, it creates an electromagnetic field that moves the relay switch arm in one direction. When the arm moves, it changes the position of the contact and closes the contacts of the output relay. The timer circuit is designed to turn on the relay switch when the P, Res and S inputs are activated and to turn off the switch after the set time interval.
As mentioned before, the DRTH24A06R time delay relay is used in a wide variety of industrial automation and process control applications. The timer circuit is used to provide a control time delay that is used to control the sequence of operations or to provide a timed release after a manual reset. It is used in industrial machinery and in industrial applications such as production lines, testing and measurement equipment, and control loops.
The DRTH24A06R is also used in system safety and security applications as a safety shut off timer. The timer is used to prevent dangerous or damaging discharges of energy in electrical and mechanical systems. The timed control element is also used in industrial monitoring systems to monitor process and system parameters such as temperature, pressure, speed, and vibration.
In conclusion, the DRTH24A06R is a versatile time delay relay that can be used in a variety of different applications. It is designed for use in industrial automation and process control systems, and system safety and security applications. The relay is capable of switching AC and DC voltages up to 500V, and the timer can be programmed for a time delay of 0.1 second to 100h. The timer circuit is used to provide a control time delay, which is used to control the sequence of operations or to provide a timed release after a manual reset.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
DRTH24D06 | Sensata-Cryd... | 39.59 $ | 20 | RELAY TIME DELAY 6A 280V ... |
DRTH24A06R | Sensata-Cryd... | 36.97 $ | 1000 | RELAY TIME DELAY 6A 280V ... |
DRTH06D06 | Sensata-Cryd... | 40.84 $ | 2 | RELAY TIME DELAY 6A 48V D... |
DRTH24A06 | Sensata-Cryd... | 38.79 $ | 3 | RELAY TIME DELAY 6A 280V ... |
DRTH24D06R | Sensata-Cryd... | 37.72 $ | 1000 | RELAY TIME DELAY 6A 280V ... |
DRTH24B06 | Sensata-Cryd... | 38.79 $ | 20 | RELAY TIME DELAY 6A 280V ... |
DRTH24B06R | Sensata-Cryd... | 38.79 $ | 20 | RELAY TIME DELAY 6A 280V ... |
SPDT DELAY ON RELEASE TIMR 10STime Delay...

COMMERCIAL 2100Time Delay Relay Delay

COMMERCIAL 2100Time Delay Relay Delay

RELAY TIME DELAYTime Delay Relay Delay

RELAY TIME DELAYTime Delay Relay Delay

RELAY TIME DELAYTime Delay Relay Delay