Allicdata Part #: | GTCR38-421M-Q10-ND |
Manufacturer Part#: |
GTCR38-421M-Q10 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Littelfuse Inc. |
Short Description: | GDT 420V 20% 10KA THROUGH HOLE |
More Detail: | Gas Discharge Tube 420V 10000A (10kA) ±20% 3 Pole ... |
DataSheet: | GTCR38-421M-Q10 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | GT |
Packaging: | Tray |
Lead Free Status / RoHS Status: | -- |
Part Status: | Obsolete |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 420V |
Impulse Discharge Current (8/20µs): | 10000A (10kA) |
Tolerance: | ±20% |
Number of Poles: | 3 |
Fail Short: | No |
Mounting Type: | Through Hole |
Package / Case: | Radial Cylinder, 3 Lead |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) are widely used to protect electrical systems from power surges caused by lightning strikes and switching operations. The GTCR38-421M-Q10 is one type of GDT that is specially designed for outdoor applications in high-rise buildings and areas prone to lightning.
The GTCR38-421M-Q10 is composed of spark gap and a gas chamber filled with SF6 (sulphur hexafluoride), and is designed to provide reliable surge protection in high voltage applications up to 780 volts. The spark gap is constructed with two electrodes. When the voltage approaches the breakdown voltage, the spark gap starts to arc, and current rapidly moves along the spark gap. When the voltage continues to increase, the current increases until an avalanche flow occurs and the gap is completely disconnected. This prevents the overvoltage from reaching sensitive electrical equipment.
The GTCR38-421M-Q10 is equipped with a built-in SF6 gas-filled chamber to further improve its surge protection capabilities. When the spark gap arcs, the electric field in the gas chamber causes ions to accelerate and generate electrons, thus forming a discharge channel in the SF6 gas. The discharge channels dissipate all the remaining surge energy and protect electrical equipment. The GTCR38-421M-Q10 is designed to protect equipment from lightning strikes and high-frequency pulse discharges. It can also be used to protect power lines and telecommunications devices in outdoor applications.
In operation, the GTCR38-421M-Q10 requires no external power supply and can be easily installed without the need for tools. Its lightweight and compact size enable it to fit into small spaces, making it suitable for most indoor and outdoor applications. The device is equipped with an indicator light to indicate the status of the arrestor. When the arrestor is in operation, the light will be lit and will turn off when it is in standby mode.
The GTCR38-421M-Q10 provides overvoltage protection for outdoor metallic systems, such as high-voltage transformers, motors, power lines, and telecommunication systems. It is ideal for high-rise buildings or locations with frequent lightning, such as coastlines or areas with active thunderstorms. The device is also suitable for use in other outdoor environments, such as industrial and agricultural areas as well as mining and utility distribution settings.
Overall, the GTCR38-421M-Q10 is an ideal solution for surge protection in areas prone to lightning and power surges. Its simple installation and maintenance-free design make it an ideal choice for outdoor applications where space is limited.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
GTCR25-601L-R05 | Littelfuse I... | 0.74 $ | 1000 | GTCR25-601L-R05 |
GTCR38-471M-R10-FS | Littelfuse I... | 0.75 $ | 1000 | GDT 470V 20% 10KA T/H FAI... |
GTCR37-151M-R10-FS | Littelfuse I... | 0.83 $ | 1000 | GDT 150V 20% 10KA T/H FAI... |
GTCR38-401M-R10 | Littelfuse I... | 0.85 $ | 1000 | GDT 400V 20% 10KA THROUGH... |
GTCR36-151M-R10 | Littelfuse I... | -- | 1000 | GDT 150V 20% 10KA THROUGH... |
GTCR36-401M-R05 | Littelfuse I... | 0.91 $ | 1000 | GDT 400V 20% 5KA THROUGH ... |
GTCR37-301M-R10 | Littelfuse I... | 0.91 $ | 1000 | GDT 300V 20% 10KA THROUGH... |
GTCR37-401M-R10 | Littelfuse I... | 0.91 $ | 1000 | GDT 400V 20% 10KA THROUGH... |
GTCR37-900M-R10 | Littelfuse I... | 0.91 $ | 1000 | GDT 90V 20% 10KA THROUGH ... |
GTCR36-351M-R10 | Littelfuse I... | 0.91 $ | 1000 | GDT 350V 20% 10KA THROUGH... |
GTCR37-351M-R10 | Littelfuse I... | 0.91 $ | 1000 | GDT 350V 20% 10KA THROUGH... |
GTCR36-351M-R10-FT | Littelfuse I... | 1.02 $ | 1000 | GDT 350V 20% 10KA T/H FAI... |
GTCR38-351M-R20 | Littelfuse I... | 1.68 $ | 1000 | GDT 350V 20% 20KA THROUGH... |
GTCR36-231M-P10 | Littelfuse I... | 0.0 $ | 1000 | GDT 230V 20% 10KA THROUGH... |
GTCR36-351M-P05 | Littelfuse I... | 0.0 $ | 1000 | GDT 350V 20% 5KA THROUGH ... |
GTCR36-900M-P05 | Littelfuse I... | 0.0 $ | 1000 | GDT 90V 20% 5KA THROUGH H... |
GTCR37-151M-P10 | Littelfuse I... | 0.0 $ | 1000 | GDT 150V 20% 10KA THROUGH... |
GTCR37-201N-P10 | Littelfuse I... | 0.0 $ | 1000 | GDT 200V 25% 10KA THROUGH... |
GTCR37-231M-P10 | Littelfuse I... | 0.0 $ | 1000 | GDT 230V 20% 10KA THROUGH... |
GTCR37-251M-P10 | Littelfuse I... | 0.0 $ | 1000 | GDT 250V 20% 10KA THROUGH... |
GTCR37-261M-P10 | Littelfuse I... | 0.0 $ | 1000 | GDT 260V 20% 10KA THROUGH... |
GTCR37-301M-P10 | Littelfuse I... | 0.0 $ | 1000 | GDT 300V 20% 10KA THROUGH... |
GTCR37-401M-P10 | Littelfuse I... | 0.0 $ | 1000 | GDT 400V 20% 10KA THROUGH... |
GTCR37-551M-P10 | Littelfuse I... | 0.0 $ | 1000 | GDT 550V 20% 10KA THROUGH... |
GTCR37-900M-P10 | Littelfuse I... | 0.0 $ | 1000 | GDT 90V 20% 10KA THROUGH ... |
GTCR38-151M-Q10 | Littelfuse I... | 0.0 $ | 1000 | GDT 150V 20% 10KA THROUGH... |
GTCR38-231M-Q10 | Littelfuse I... | 0.0 $ | 1000 | GDT 230V 20% 10KA THROUGH... |
GTCR38-251M-Q10 | Littelfuse I... | 0.0 $ | 1000 | GDT 250V 20% 10KA THROUGH... |
GTCR38-351M-P20 | Littelfuse I... | 0.0 $ | 1000 | GDT 350V 20% 20KA THROUGH... |
GTCR38-351M-Q10 | Littelfuse I... | 0.0 $ | 1000 | GDT 350V 20% 10KA THROUGH... |
GTCR38-421M-Q10 | Littelfuse I... | 0.0 $ | 1000 | GDT 420V 20% 10KA THROUGH... |
GTCR38-501M-Q10 | Littelfuse I... | 0.0 $ | 1000 | GDT 500V 20% 10KA THROUGH... |
GTCR38-900M-Q10 | Littelfuse I... | 0.0 $ | 1000 | GDT 90V 20% 10KA THROUGH ... |
GTCR36-231M-P10-FS | Littelfuse I... | 0.0 $ | 1000 | GDT 230V 20% 10KA T/H FAI... |
GTCR36-351M-P05-FS | Littelfuse I... | 0.0 $ | 1000 | GDT 350V 20% 5KA T/H FAIL... |
GTCR36-900M-P05-FS | Littelfuse I... | 0.0 $ | 1000 | GDT 90V 20% 5KA T/H FAIL ... |
GTCR37-151M-P10-FS | Littelfuse I... | 0.0 $ | 1000 | GDT 150V 20% 10KA T/H FAI... |
GTCR37-201N-P10-FS | Littelfuse I... | 0.0 $ | 1000 | GDT 200V 25% 10KA T/H FAI... |
GTCR37-231M-P10-FS | Littelfuse I... | 0.0 $ | 1000 | GDT 230V 20% 10KA T/H FAI... |
GTCR37-261M-P10-FS | Littelfuse I... | 0.0 $ | 1000 | GDT 260V 20% 10KA T/H FAI... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...