
Allicdata Part #: | HF2826-802Y2R0T01-ND |
Manufacturer Part#: |
HF2826-802Y2R0-T01 |
Price: | $ 0.00 |
Product Category: | Filters |
Manufacturer: | TDK Corporation |
Short Description: | COMMON MODE CHOKE 2A 2LN TH |
More Detail: | 2 Line Common Mode Choke Through Hole 2A DCR 180 ... |
DataSheet: | ![]() |
Quantity: | 1000 |
1 +: | 0.00000 |
Voltage Rating - AC: | -- |
Package / Case: | Vertical, 4 PC Pin |
Height (Max): | 1.024" (26.00mm) |
Size / Dimension: | 1.201" L x 1.201" W (30.50mm x 30.50mm) |
Mounting Type: | Through Hole |
Features: | -- |
Approvals: | -- |
Ratings: | -- |
Operating Temperature: | -20°C ~ 120°C |
Series: | HF |
Voltage Rating - DC: | -- |
DC Resistance (DCR) (Max): | 180 mOhm |
Current Rating (Max): | 2A |
Number of Lines: | 2 |
Filter Type: | Power Line |
Part Status: | Obsolete |
Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Common Mode Chokes play a crucial role in safeguarding sensitive equipment from electrical interference. This is especially true of HF2826-802Y2R0-T01 application field and its working principle. These applications and principles can be broken down into two main categories: power supply and inverter applications.
Power supply applications mainly use HF2826-802Y2R0-T01 common mode chokes to reduce the level of interference that is picked up by power cables. This helps to ensure that high quality and reliable power supply is delivered to the equipment it is servicing. The choke works by passing current through a coil while blocking the interfering noise. As such, the current is diverted before reaching the power connector and the noise is blocked and unable to interfere with the power supply.
Inverter applications require the HF2826-802Y2R0-T01 common mode choke for the exact same purpose. Inverters are used to convert direct current (DC) into alternating current (AC). The noise that is picked up on the DC power cables must be blocked in order to ensure the proper voltage and current is received by the inverter. As in the previous example, the common mode choke works by passing current through a coil while blocking the interfering noise.
In addition to providing cleaner and more reliable power, common mode chokes also help to eliminate ground loops that may be induced into the power system. Ground loops are caused by an imbalance between the power and ground lines. If the power and ground lines are not properly balanced, electrical noise and interference can be caused. To avoid this, a common mode choke can be used to balance the power and ground lines, thus eliminating any unwanted ground loops.
HF2826-802Y2R0-T01 common mode chokes are also used to reduce the amount of radiation emitted from multiple electrical devices. This is done by blocking the radiation caused by the power cables and devices. As the radiation is blocked, it is unable to escape from the system and interfere with adjacent devices. This is especially beneficial in devices that require maximum performance and reliability.
In addition, common mode chokes are often used to reduce external interference from outside sources. This is done by using galvanic isolation to isolate the power lines from external interference. By isolating the power supply, the amount of noise and interference that is picked up and heard over a wide range of frequencies is greatly reduced.
HF2826-802Y2R0-T01 common mode chokes are also beneficial in preventing voltage spikes and electrical surges. In certain power systems, inductive loads may cause voltage spikes. To prevent this, these common mode chokes can be used to absorb the voltage spikes before they reach the equipment or device.
Overall, HF2826-802Y2R0-T01 common mode chokes provide a reliable and effective way to reduce the amount of interference caused by power cables and devices. By forming an inductive barrier, they help to ensure that the power supply is safe and reliable while still delivering the desired performance. Additionally, they help to eliminate ground loops, reduce radiation, and block external interference. With their many benefits and applications, it is no surprise that common mode chokes are an essential component in many sensitive power systems.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
HF2827-123Y1R5-01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 1.5A 2L... |
HF2826-472Y2R8-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 2.8A 2L... |
HF2826-123Y1R8-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 1.8A 2L... |
HF2836-562Y2R5-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 2.5A 2L... |
HF2826-802Y2R0-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 2A 2LN ... |
HF2827-442Y2R5-01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 2.5A 2L... |
HF2836-332Y3R0-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 3A 2LN ... |
HF28B2038 | Leader Tech ... | 28.71 $ | 1000 | FERRITE 410OHM HINGED 11.... |
HF2826-182Y4R0-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 4A 2LN ... |
HF2836-802Y2R0-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 2A 2LN ... |
HF2836-353Y1R0-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 1A 2LN ... |
HF2836-472Y2R8-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 2.8A 2L... |
HF2827-252Y3R0-01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 3A 2LN ... |
HF2826-332Y3R0-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 3A 2LN ... |
HF28B2039 | Leader Tech ... | 28.92 $ | 1000 | FERRITE 410OHM HINGED 11M... |
HF2827-602Y2R0-01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 2A 2LN ... |
HF2827-183Y1R0-01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 1A 2LN ... |
HF2826-353Y1R0-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 1A 2LN ... |
HF2827-303Y0R9-01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 900MA 2... |
HF2836-123Y1R8-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 1.8A 2L... |
HF2836-182Y4R0-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 4A 2LN ... |
HF2826-203Y1R5-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 1.5A 2L... |
HF2826-562Y2R5-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 2.5A 2L... |
HF2836-203Y1R5-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 1.5A 2L... |
HF2826-253Y1R2-T01 | TDK Corporat... | 0.0 $ | 1000 | COMMON MODE CHOKE 1.2A 2L... |
CMC 100MH 400MA 2LN TH100mH @ 10kHz 2 Li...

COMMON MODE CHOKE 27MH 1A 2LN TH27mH @ 1...

CMC 3.3MH 1.2A 2LN TH3.3mH @ 10kHz 2 Lin...

COMMON MODE CHOKE 13MH 2A 2LN TH13mH @ 1...

COMMON MODE CHOKE 1.3A 2LN TH2 Line Comm...

COMMON MODE CHOKE 1MH 20A 2LN TH1mH @ 10...
