HLSR 10-P/SP33 Sensors, Transducers |
|
Allicdata Part #: | 398-1131-ND |
Manufacturer Part#: |
HLSR 10-P/SP33 |
Price: | $ 9.14 |
Product Category: | Sensors, Transducers |
Manufacturer: | LEM USA Inc. |
Short Description: | SENSOR CURRENT HALL 10A AC/DC |
More Detail: | Current Sensor 10A 1 Channel Hall Effect, Open Loo... |
DataSheet: | HLSR 10-P/SP33 Datasheet/PDF |
Quantity: | 314 |
1 +: | $ 8.30340 |
5 +: | $ 8.13456 |
10 +: | $ 6.77880 |
25 +: | $ 6.27052 |
50 +: | $ 6.10092 |
100 +: | $ 5.25357 |
500 +: | $ 4.91463 |
1000 +: | $ 4.66043 |
Frequency: | 400kHz |
Package / Case: | Module |
Mounting Type: | Through Hole |
Polarization: | Bidirectional |
Operating Temperature: | -40°C ~ 105°C |
Current - Supply (Max): | 25mA |
Response Time: | 2.5µs |
Voltage - Supply: | 3.3V |
Accuracy: | ±1% |
Linearity: | ±0.5% |
Series: | HLSR-P |
Sensitivity: | 80mV/A |
Output: | Ratiometric, Voltage |
Number of Channels: | 1 |
Current - Sensing: | 10A |
Sensor Type: | Hall Effect, Open Loop |
For Measuring: | AC/DC |
Part Status: | Active |
Packaging: | Tray |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Current transducers are essential in measuring and converging various electrical signals from a system. The HLSR 10-P/SP33 current transducer is a robust device that is able to automatically detect current signals in a variety of applications. It is designed to be used in industrial, commercial, medical, and military applications. This article will discuss the application field and working principle of the HLSR 10-P/SP33 current transducer.
The HLSR 10-P/SP33 is a full-bridge current transducer that is designed to measure and convert electrical signals. It is a three-wire device, meaning it is suitable for both single-phase and three-phase applications. It operates by converting the current signal to a voltage signal, with a focus on accuracy, reliability, and protection. The device is rated for a total current range of 0-200A.
In terms of its application field, it is suitable for a variety of applications including industrial, commercial, medical, and military. In the industrial sector, it can be used to detect current flow in power distribution systems, motor controls, heating and ventilation systems, and renewable energy systems. In the commercial setting, it can be used for detecting building loads, lighting systems, and electronic devices. It can also be used for surge protection and overcurrent protection in medical and military settings.
The working principle of the HLSR 10-P/SP33 can be broken down further into the two main components of a current transducer: the sensing element and the transducer block. The sensing element of the device consists of a magnetic ring, a Hall effect sensor, and a permanent magnet. The magnetic ring is used to generate a magnetic field when current flows through it. The Hall effect sensor is then used to measure the strength of this magnetic field, which is then converted into an electrical signal. The permanent magnet helps to keep the magnetic field constant, ensuring that the measurements are accurate and consistent.
The transducer block is responsible for the conversion of the electrical signal, as well as providing the device with protection. It contains an ore amplifier, filter networks, and a relays and voltage transformers. The ore amplifier is used to amplify the signal from the Hall effect sensor, while the filter networks are there to reduce noise and interference. The relays are used to provide protection against overcurrent and overvoltages, while voltage transformers are there for measuring and controlling voltage signals.
In conclusion, the HLSR 10-P/SP33 current transducer is an accurate, reliable, and robust device that is suitable for a variety of applications. The device is designed to convert electrical signals into voltage signals, with the help of its two main components – the sensing element and the transducer block. With its wide range of applications, it is ideal for both single-phase and three-phase settings. It is also ideal for applications such as surge protection, overcurrent protection, energy distribution systems, and motor control.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
HLSR 20-P | LEM USA Inc. | 9.14 $ | 942 | SENSOR CURRENT HALL 20A A... |
HLSR 40-P | LEM USA Inc. | 9.14 $ | 665 | SENSOR CURRENT HALL 40A A... |
HLSR 50-P | LEM USA Inc. | 9.14 $ | 463 | SENSOR CURRENT HALL 50A A... |
HLSR 20-P/SP33 | LEM USA Inc. | 9.14 $ | 390 | SENSOR CURRENT HALL 20A A... |
HLSR 32-SM | LEM USA Inc. | 8.5 $ | 202 | SENSOR CURRENT HALL 32A A... |
HLSR 10-P | LEM USA Inc. | -- | 307 | SENSOR CURRENT HALL 10A A... |
HLSR 50-P/SP33 | LEM USA Inc. | 9.14 $ | 256 | SENSOR CURRENT HALL 50A A... |
HLSR 10-SM/SP33 | LEM USA Inc. | 8.5 $ | 285 | SENSOR CURRENT HALL 10A A... |
HLSR 20-SM | LEM USA Inc. | 8.5 $ | 282 | SENSOR CURRENT HALL 20A A... |
HLSR 10-SM | LEM USA Inc. | 8.5 $ | 220 | SENSOR CURRENT HALL 10A A... |
HLSR 10-P/SP33 | LEM USA Inc. | 9.14 $ | 314 | SENSOR CURRENT HALL 10A A... |
HLSR 20-SM/SP33 | LEM USA Inc. | 8.5 $ | 400 | SENSOR CURRENT HALL 20A A... |
HLSR 50-SM | LEM USA Inc. | 8.5 $ | 313 | SENSOR CURRENT HALL 50A A... |
HLSR 32-P/SP33 | LEM USA Inc. | 9.14 $ | 67 | SENSOR CURRENT HALL 32A A... |
HLSR 32-P | LEM USA Inc. | -- | 4425 | SENSOR CURRENT HALL 32A A... |
HLSR 50-SM/SP33 | LEM USA Inc. | 8.5 $ | 75 | SENSOR CURRENT HALL 50A A... |
HLSR 40-P/SP33 | LEM USA Inc. | 9.14 $ | 1000 | SENSOR CURRENT HALL 40A A... |
HLSR 32-SM/SP33 | LEM USA Inc. | 4.63 $ | 1000 | SENSOR CURRENT HALL 32A A... |
HLSR 40-SM | LEM USA Inc. | 4.63 $ | 1000 | SENSOR CURRENT HALL 40A A... |
HLSR 40-SM/SP33 | LEM USA Inc. | 5.52 $ | 1000 | SENSOR CURRENT HALL 40A A... |
SENSOR CURRENT XFMR 40A ACCurrent Sensor...
SENSOR CURRENT XFMR 5A ACCurrent Sensor ...
SENSOR CURRENT HALL 15A AC/DCCurrent Sen...
3 PIECE KIT SENSOR CURRENT HALLCurrent S...
PACT RCP-4000A-1A-D190Current Sensor 100...
SENSOR CURRENT HALL 30A DCCurrent Sensor...