HLSR 10-P Sensors, Transducers |
|
Allicdata Part #: | 398-1121-ND |
Manufacturer Part#: |
HLSR 10-P |
Price: | $ 0.00 |
Product Category: | Sensors, Transducers |
Manufacturer: | LEM USA Inc. |
Short Description: | SENSOR CURRENT HALL 10A AC/DC |
More Detail: | Current Sensor 10A 1 Channel Hall Effect, Open Loo... |
DataSheet: | HLSR 10-P Datasheet/PDF |
Quantity: | 307 |
Frequency: | 400kHz |
Package / Case: | Module |
Mounting Type: | Through Hole |
Polarization: | Bidirectional |
Operating Temperature: | -40°C ~ 105°C |
Current - Supply (Max): | 25mA |
Response Time: | 2.5µs |
Voltage - Supply: | 5V |
Accuracy: | ±1% |
Linearity: | ±0.5% |
Series: | HLSR-P |
Sensitivity: | 80mV/A |
Output: | Ratiometric, Voltage |
Number of Channels: | 1 |
Current - Sensing: | 10A |
Sensor Type: | Hall Effect, Open Loop |
For Measuring: | AC/DC |
Part Status: | Active |
Packaging: | Tray |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Current transducers are used to measure electrical signals that represent magnitude and direction of current flowing through electrical transmission or distribution systems. One of the most commonly used type is the HLSR 10-P, which converts current into a proportional output signal that can be monitored and controlled. This article will discuss the application field and working principle of the HLSR 10-P current transducer.
Application Field:
The HLSR 10-P current transducer is widely used in many industries such as automotive, power grids, telecommunications, power management, and IT systems. It is ideal for applications that require precise current measurement, such as providing feedback on current usage for battery powered equipment, monitoring current from power plants or other large facilities, or accurately measuring current for applications where load shedding and monitoring is needed. In addition, it is also used in electric motor control systems because it can effectively measure a wide range of frequencies.
Working Principle:
The HLSR 10-P current transducer operates on the principle of electromagnetic induction. It consists of two coils: the primary coil which is connected to the line voltage and current, and the secondary coil which is connected to the circuits that need to be monitored. When a current passes through the primary coil, it generates a magnetic field, which then induces an AC voltage in the secondary coil. This voltage is then converted into a proportional output signal, which can then be monitored and controlled. The output signal is then used to provide information on the magnitude and direction of the current.
The output signal from the HLSR 10-P current transducer can be monitored by a digital display or a device such as a computer, which enables it to be used as a remote measuring and monitoring device. The output signal can also be used to control various electrical systems, such as power cut-offs, load shedding and motor control.
Advantages:
The HLSR 10-P current transducer has several advantages over other types. First, it is more accurate than traditional current sensors because the output signal is proportional to the current. Second, it is very resistant to variation, making it suitable for use in a wide range of applications. Third, it is a low cost and low maintenance solution, meaning that it does not need to be replaced frequently. Finally, it is very durable and will last a long time.
Conclusion:
The HLSR 10-P current transducer is an excellent choice for accurate, robust current measurement and control. It is widely used in a variety of industries and application fields, offering precision measurement and control. In addition, it is simple to install and maintain, and is very cost-effective. Overall, the HLSR 10-P current transducer is a great choice for anyone who needs precise and reliable current measurement.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
HLSR 20-P | LEM USA Inc. | 9.14 $ | 942 | SENSOR CURRENT HALL 20A A... |
HLSR 40-P | LEM USA Inc. | 9.14 $ | 665 | SENSOR CURRENT HALL 40A A... |
HLSR 50-P | LEM USA Inc. | 9.14 $ | 463 | SENSOR CURRENT HALL 50A A... |
HLSR 20-P/SP33 | LEM USA Inc. | 9.14 $ | 390 | SENSOR CURRENT HALL 20A A... |
HLSR 32-SM | LEM USA Inc. | 8.5 $ | 202 | SENSOR CURRENT HALL 32A A... |
HLSR 10-P | LEM USA Inc. | -- | 307 | SENSOR CURRENT HALL 10A A... |
HLSR 50-P/SP33 | LEM USA Inc. | 9.14 $ | 256 | SENSOR CURRENT HALL 50A A... |
HLSR 10-SM/SP33 | LEM USA Inc. | 8.5 $ | 285 | SENSOR CURRENT HALL 10A A... |
HLSR 20-SM | LEM USA Inc. | 8.5 $ | 282 | SENSOR CURRENT HALL 20A A... |
HLSR 10-SM | LEM USA Inc. | 8.5 $ | 220 | SENSOR CURRENT HALL 10A A... |
HLSR 10-P/SP33 | LEM USA Inc. | 9.14 $ | 314 | SENSOR CURRENT HALL 10A A... |
HLSR 20-SM/SP33 | LEM USA Inc. | 8.5 $ | 400 | SENSOR CURRENT HALL 20A A... |
HLSR 50-SM | LEM USA Inc. | 8.5 $ | 313 | SENSOR CURRENT HALL 50A A... |
HLSR 32-P/SP33 | LEM USA Inc. | 9.14 $ | 67 | SENSOR CURRENT HALL 32A A... |
HLSR 32-P | LEM USA Inc. | -- | 4425 | SENSOR CURRENT HALL 32A A... |
HLSR 50-SM/SP33 | LEM USA Inc. | 8.5 $ | 75 | SENSOR CURRENT HALL 50A A... |
HLSR 40-P/SP33 | LEM USA Inc. | 9.14 $ | 1000 | SENSOR CURRENT HALL 40A A... |
HLSR 32-SM/SP33 | LEM USA Inc. | 4.63 $ | 1000 | SENSOR CURRENT HALL 32A A... |
HLSR 40-SM | LEM USA Inc. | 4.63 $ | 1000 | SENSOR CURRENT HALL 40A A... |
HLSR 40-SM/SP33 | LEM USA Inc. | 5.52 $ | 1000 | SENSOR CURRENT HALL 40A A... |
SENSOR CURRENT XFMR 40A ACCurrent Sensor...
SENSOR CURRENT XFMR 5A ACCurrent Sensor ...
SENSOR CURRENT HALL 15A AC/DCCurrent Sen...
3 PIECE KIT SENSOR CURRENT HALLCurrent S...
PACT RCP-4000A-1A-D190Current Sensor 100...
SENSOR CURRENT HALL 30A DCCurrent Sensor...