Allicdata Part #: | 317-1165-ND |
Manufacturer Part#: |
MF72-022D9 |
Price: | $ 0.28 |
Product Category: | Circuit Protection |
Manufacturer: | Cantherm |
Short Description: | ICL 22 OHM 20% 1A 11MM |
More Detail: | Inrush Current Limiter 22 Ohms ±20% 1A 0.433" (11m... |
DataSheet: | MF72-022D9 Datasheet/PDF |
Quantity: | 1734 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
1 +: | $ 0.25200 |
5 +: | $ 0.24570 |
10 +: | $ 0.23877 |
50 +: | $ 0.20072 |
100 +: | $ 0.16657 |
250 +: | $ 0.15145 |
500 +: | $ 0.12872 |
1000 +: | $ 0.11358 |
5000 +: | $ 0.10222 |
Series: | MF72 |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
R @ 25°C: | 22 Ohms |
Tolerance: | ±20% |
Current - Steady State Max: | 1A |
R @ Current: | 950 mOhms |
Diameter: | 0.433" (11mm) |
Lead Spacing: | 0.295" (7.50mm) |
Approvals: | -- |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Inrush Current Limiters (ICL) are a type of active protective device used to limit the surge of electric currents (inrush currents) that may occur in circuits at the time of energization or at the time of switching between circuits. The MF72-022D9 is a popular ICL used in many applications, and its working principles can be understood best by examining what happens when the device is used.
When the MF72-022D9 is energized, it initially draws a very high amount of current from the power source. This surge of current, or inrush current, can damage sensitive components or other electronic equipment. Through careful design, the MF72-022D9 has the capability to limit this surge of current before it damage electronic equipment.
A brief overview of the device can help explain the working principle. The MF72-022D9 contains a high voltage rectifier, a resistor, and a thyristor. The rectifier and resistor form a voltage divider network which divides the voltage of the input power source. This voltage is applied to the gate of the thyristor, and it determines the current level that the thyristor will allow to pass through.
At low levels of input voltage, the thyristor will remain off, and no current is allowed to pass through. However, as the voltage increases, the thyristor eventually reaches its threshold, and it turns on. This allows a small amount of current to pass through, which prevents the inrush current from reaching dangerous levels.
When the input voltage decreases or the load is removed, the thyristor turns off and the current through it is limited. This prevents transient currents from occurring that could damage electronic equipment. The result is a device that can both protect electronic equipment from inrush current and limit the transient current during operation.
The MF72-022D9 can be found in a variety of applications and is widely used in ac-dc power supplies, motor control systems, and lighting systems. It is also used in medical systems, where it can be used to prevent electrical shocks and to limit the amount of current flowing through sensitive components. Additionally, it can be used in surge protection devices and in communication systems to limit the amount of surge current that can flow through sensitive communication lines.
The MF72-022D9 can also be used to protect against overvoltage and overcurrent conditions. It is designed to limit the amount of current that can pass through it at a given voltage, and provides protection against transient conditions. This can be especially useful in high-powered equipment, where the current can exceed the rated levels in a matter of seconds and cause permanent damage.
Overall, the MF72-022D9 is a highly effective inrush current limiter that is widely used in a variety of applications. Its design ensures that it can provide protection against both high and low levels of current, while also preventing transient overvoltage and overcurrent conditions. It can be used in power supplies, motor control systems, and lighting systems, as well as in communication and medical systems, where its many advantageous features can be put to good use.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
MF72-200D5 | Cantherm | 0.26 $ | 20118 | ICL 200 OHM 20% 100MA 7MM... |
MF72-060D5 | Cantherm | 0.26 $ | 19466 | ICL 60 OHM 20% 300MA 7MMI... |
MF72-010D5 | Cantherm | -- | 11243 | ICL 10 OHM 20% 700MA 7MMI... |
MF72-050D9 | Cantherm | 0.28 $ | 13868 | ICL 50 OHM 20% 1A 11MMInr... |
MF72-120D13 | Cantherm | 0.58 $ | 12125 | ICL 120 OHM 20% 1.2A 15.5... |
MF72-003D25 | Cantherm | 3.61 $ | 1238 | ICL 3 OHM 20% 9A 27.5MMIn... |
MF72-016D7 | Cantherm | 0.26 $ | 21511 | ICL 16 OHM 20% 700MA 9MMI... |
MF72-010D7 | Cantherm | 0.26 $ | 6016 | ICL 10 OHM 20% 1A 9MMInru... |
MF72-033D7 | Cantherm | 0.26 $ | 4893 | ICL 33 OHM 20% 500MA 9MMI... |
MF72-022D7 | Cantherm | 0.26 $ | 2897 | ICL 22 OHM 20% 600MA 9MMI... |
MF72-012D7 | Cantherm | 0.26 $ | 2881 | ICL 12 OHM 20% 1A 9MMInru... |
MF72-005D5 | Cantherm | 0.26 $ | 2417 | ICL 5 OHM 20% 1A 7MMInrus... |
MF72-120D9 | Cantherm | 0.28 $ | 12995 | ICL 120 OHM 20% 800MA 11M... |
MF72-200D9 | Cantherm | 0.28 $ | 8997 | ICL 200 OHM 20% 500MA 11M... |
MF72-080D9 | Cantherm | 0.28 $ | 8217 | ICL 80 OHM 20% 800MA 11MM... |
MF72-004D9 | Cantherm | 0.28 $ | 5565 | ICL 4 OHM 20% 3A 11MMInru... |
MF72-012D9 | Cantherm | 0.28 $ | 1852 | ICL 12 OHM 20% 1A 11MMInr... |
MF72-010D9 | Cantherm | 0.28 $ | 5398 | ICL 10 OHM 20% 2A 11MMInr... |
MF72-020D9 | Cantherm | 0.28 $ | 2611 | ICL 20 OHM 20% 1A 11MMInr... |
MF72-003D9 | Cantherm | 0.28 $ | 2491 | ICL 3 OHM 20% 4A 11MMInru... |
MF72-022D9 | Cantherm | 0.28 $ | 1734 | ICL 22 OHM 20% 1A 11MMInr... |
MF72-060D9 | Cantherm | 0.28 $ | 1267 | ICL 60 OHM 20% 800MA 11MM... |
MF72-400D9 | Cantherm | 0.28 $ | 1091 | ICL 400 OHM 20% 200MA 11M... |
MF72-003D11 | Cantherm | 0.33 $ | 4598 | ICL 3 OHM 20% 5A 13MMInru... |
MF72-022D11 | Cantherm | 0.33 $ | 3883 | ICL 22 OHM 20% 2A 13MMInr... |
MF72-002.5D11 | Cantherm | 0.33 $ | 2472 | ICL 2.5 OHM 20% 5A 13MMIn... |
MF72-030D11 | Cantherm | 0.33 $ | 2074 | ICL 30 OHM 20% 1.5A 13MMI... |
MF72-010D11 | Cantherm | 0.33 $ | 1170 | ICL 10 OHM 20% 3A 13MMInr... |
MF72-001.3D13 | Cantherm | 0.58 $ | 4034 | ICL 1.3 OHM 20% 7A 15.5MM... |
MF72-005D13 | Cantherm | 0.58 $ | 1881 | ICL 5 OHM 20% 5A 15.5MMIn... |
MF72-005D15 | Cantherm | 0.8 $ | 1841 | ICL 5 OHM 20% 6A 17.5MMIn... |
MF72-047D15 | Cantherm | 0.8 $ | 1668 | ICL 47 OHM 20% 3A 17.5MMI... |
MF72-010D20 | Cantherm | 2.29 $ | 750 | ICL 10 OHM 20% 6A 22.5MMI... |
MF72-005D20 | Cantherm | 2.29 $ | 215 | ICL 5 OHM 20% 7A 22.5MMIn... |
MF72-008D7 | Cantherm | 0.26 $ | 1409 | ICL 8 OHM 20% 1A 9MMInrus... |
MF72-008D9 | Cantherm | 0.28 $ | 3159 | ICL 8 OHM 20% 2A 11MMInru... |
MF72-006D9 | Cantherm | 0.28 $ | 1539 | ICL 6 OHM 20% 2A 11MMInru... |
MF72-012D11 | Cantherm | 0.33 $ | 4352 | ICL 12 OHM 20% 2A 13MMInr... |
MF72-060D11 | Cantherm | 0.33 $ | 3076 | ICL 60 OHM 20% 1.5A 13MMI... |
MF72-016D11 | Cantherm | 0.33 $ | 1904 | ICL 16 OHM 20% 2A 13MMInr... |
ICL 1.3 OHM 25% 8A 13.97MMInrush Current...
ICL 10 OHM 20% 5A 12MMInrush Current Lim...
ICL 4 OHM 20% 23A 30MMInrush Current Lim...
ICL 16 OHM 20% 4A 22MMInrush Current Lim...
ICL 16 OHM 25% 4A 19.56MMInrush Current ...
ICL 33 OHM 20% 2.5A 15MMInrush Current L...