Allicdata Part #: | 570-1286-ND |
Manufacturer Part#: |
SL10 2R505-A |
Price: | $ 0.28 |
Product Category: | Circuit Protection |
Manufacturer: | Ametherm |
Short Description: | ICL 2.5 OHM 30% 5A 10MM |
More Detail: | Inrush Current Limiter 2.5 Ohms ±30% 5A 0.394" (10... |
DataSheet: | SL10 2R505-A Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
400 +: | $ 0.24948 |
Series: | SL10 |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
R @ 25°C: | 2.5 Ohms |
Tolerance: | ±30% |
Current - Steady State Max: | 5A |
R @ Current: | 120 mOhms |
Diameter: | 0.394" (10mm) |
Lead Spacing: | 0.197" (5.00mm) |
Approvals: | CSA, UR |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Inrush Current Limiters (ICLs) are components in electrical engineering used to limit inrush current, usually when a device is being powered on. Thermal, resistive or inductive inrush current limiters are the three main types.
The SL10 2R505-A Inrush Current Limiter is a NTC Thermistor based inrush current limiter that is designed to limit the amount of inrush current for different power supply and load application across China. It is recommended for applications that require a temperature range of -40 to +85°C.
The SL10 2R505-A Inrush Current Limiter works by utilizing the mission of a PTC thermistor, both the ambient temperature and the peak temperature of the inrush current will affect the resistance of the thermistor. Typically, when power is applied to the inrush current limiter, the resistance is very low, allowing the current to pass through. When the current passing through the inrush current limiter has exceeded a certain peak point, the temperature of the limiter will rise rapidly. This heightens the resistance of the thermistor, limiting further current. The thermistor will cool gradually after the initial peak current has decreased, allowing the resistance to slowly decrease, enabling current to pass through again.
The SL10 2R505-A can be used to limit a maximum of 100A of inrush current within a few milliseconds when connected across the power supply. It is suitable for a voltage of 250VAC and a temperature range of -40°C to +85°C, with a power of 220W.
An SL10 2R505-A inrush current limiter is commonly used in air-conditioners, power supplies, automotive electrical systems, lighting control, and power conversion appliances. In particular, power generators, UPS systems, transformers, electric motors and LED driver. Many times these appliances require a large burst of power when first powered on, and the inrush current limiter prevents too much power from being drawn -- by not allowing current to exceed the set limit, the inrush current limiter ensures that the appliance is not damaged.
The SL10 2R505-A inrush current limiter works on the principle that when an electronic product is connected to the power supply,the current is momentarily excessive. A current limiter allows this excess current to flow, and in doing so, it dissipates a certain amount of power and creates a fixed amount of current. This current is then consumed by the system, which reduces the amount of heat generated during the inrush current, and helps to protect the system.
A major benefit of using an SL10 2R505-A inrush current limiter is that it helps to reduce the stress on the power cables and circuit Breaker, as the inrush current is controlled and the amount of heat produced is minimal. Furthermore, it also helps reduce the possibility of tripping the breaker due to high inrush current loads, thus avoiding costly system re-starts or component replacements. It also helps to maintain consistency in power supplies, reducing the chances of system crashes due to current overloads.
In conclusion, the SL10 2R505-A Inrush Current Limiter is an important component in electrical engineering used to limit inrush current from electrical appliances, preventing a high inrush current from damaging the system. It is commonly used in air-conditioners, power supplies, automotive electrical systems, lighting control, and power conversion appliances. By limiting the initial inrush current, the SL10 2R505-A Inrush Current Limiter helps to reduce the stress on power cables and circuit breakers while ensuring the system is not damaged by a sudden surge of power.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
HLMP-SL10-HL0DD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LM0DD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LMKDD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LMLDD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LPKDD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-MNK00 | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-MNKDD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-MP0DD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-MQLDD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LP000 | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LP0DD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-MNLDD | Broadcom Lim... | 0.0 $ | 1000 | HLMP-SL10-MNLDDLED Indica... |
SL1053B-NL | Littelfuse I... | 27.4 $ | 174 | HOLDER MOUNT FOR GAS TUBE... |
SL1011A075C | Littelfuse I... | 0.0 $ | 1000 | GDT 75V 5KAGas Discharge ... |
SL1011A145C | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 5KAGas Discharge... |
SL1011A400A | Littelfuse I... | 0.0 $ | 1000 | GDT 400V 5KA THROUGH HOLE... |
SL1011A400C | Littelfuse I... | 0.0 $ | 1000 | GDT 400V 5KAGas Discharge... |
SL1011B075A | Littelfuse I... | 0.0 $ | 1000 | GDT 75V 10KA THROUGH HOLE... |
SL1011B145A | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KA THROUGH HOL... |
SL1011B145C | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KAGas Discharg... |
SL1011B250C | Littelfuse I... | 0.0 $ | 1000 | GDT 250V 10KAGas Discharg... |
SL1021A090RS | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KA THROUGH HOL... |
SL1021A145C | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KAGas Discharg... |
SL1021A145R | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KA THROUGH HOL... |
SL1021A145RF | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KA T/H FAIL SH... |
SL1021A145RS | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KA THROUGH HOL... |
SL1021A150C | Littelfuse I... | 0.0 $ | 1000 | GDT 150V 10KAGas Discharg... |
SL1021A150RF | Littelfuse I... | 0.0 $ | 1000 | GDT 150V 10KA T/H FAIL SH... |
SL1021A150RS | Littelfuse I... | 0.0 $ | 1000 | GDT 200V 10KA THROUGH HOL... |
SL1021A200RS | Littelfuse I... | 0.0 $ | 1000 | GDT 200V 10KA THROUGH HOL... |
SL1021A230RS | Littelfuse I... | 0.0 $ | 1000 | GDT 230V 10KA THROUGH HOL... |
SL1021A250RS | Littelfuse I... | 0.0 $ | 1000 | GDT 260V 10KA THROUGH HOL... |
SL1021A260RS | Littelfuse I... | 0.0 $ | 1000 | GDT 260V 10KA THROUGH HOL... |
SL1021A300RS | Littelfuse I... | 0.0 $ | 1000 | GDT 300V 10KA THROUGH HOL... |
SL1021A350RS | Littelfuse I... | 0.0 $ | 1000 | GDT 350V 10KA THROUGH HOL... |
SL1021A400RS | Littelfuse I... | 0.0 $ | 1000 | GDT 400V 10KA THROUGH HOL... |
SL1021A420RS | Littelfuse I... | 0.0 $ | 1000 | GDT 420V 10KA THROUGH HOL... |
SL1021A450RS | Littelfuse I... | 0.0 $ | 1000 | GDT 450V 10KA THROUGH HOL... |
SL1021A500RS | Littelfuse I... | 0.0 $ | 1000 | GDT 500V 10KA THROUGH HOL... |
SL1021A600RS | Littelfuse I... | 0.0 $ | 1000 | GDT 600V 10KA THROUGH HOL... |
ICL 1.3 OHM 25% 8A 13.97MMInrush Current...
ICL 10 OHM 20% 5A 12MMInrush Current Lim...
ICL 4 OHM 20% 23A 30MMInrush Current Lim...
ICL 16 OHM 20% 4A 22MMInrush Current Lim...
ICL 16 OHM 25% 4A 19.56MMInrush Current ...
ICL 33 OHM 20% 2.5A 15MMInrush Current L...