Allicdata Part #: | 570-1288-ND |
Manufacturer Part#: |
SL10 4R004-A |
Price: | $ 0.28 |
Product Category: | Circuit Protection |
Manufacturer: | Ametherm |
Short Description: | ICL 4 OHM 20% 4A 10MM |
More Detail: | Inrush Current Limiter 4 Ohms ±20% 4A 0.394" (10mm... |
DataSheet: | SL10 4R004-A Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
400 +: | $ 0.24948 |
Series: | SL10 |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
R @ 25°C: | 4 Ohms |
Tolerance: | ±20% |
Current - Steady State Max: | 4A |
R @ Current: | 140 mOhms |
Diameter: | 0.394" (10mm) |
Lead Spacing: | 0.248" (6.30mm) |
Approvals: | CSA, UR |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
In the world of power control systems, Inrush Current Limiters (ICLs) are a key component for a variety of different applications. SL10 4R004-A ICLs are no exception, proving to be particularly useful in a variety of industrial and commercial control systems as well as motor control applications.
SL10 4R004-A ICLs are designed to limit peak inrush currents in applications where short-term overloads can cause the circuit to trip or reduce the durability of the system. Inrush current limiters are used to prevent surge currents when a large load is suddenly connected to the circuit, or when there is an interruption in the power supply.
In addition to current limiting applications, SL10 4R004-A ICLs can also be used for high-voltage circuit protection, particularly when rapid voltage changes take place. This type of ICL is often used in high-efficiency controllers, for example, in order to protect from over currents due to fast turning on and off, or within motor drives applications, to offer current limitation during short-term overloads.
SL10 4R004-A ICLs also have the ability to detect voltage diodes and generally act as current limiting devices that take into account the inductive nature of the circuit. As the inrush-current limiter detects voltage drops in the circuit, it will limit the current in order to ensure safe and proper operation for the load. This type of ICL can also be used in circuits that are susceptible to surge currents, as it can accurately detect and neutralize the surge.
In terms of operation, SL10 4R004-A ICLs employ a rectifying structure that is connected between the power supply and the load to be protected. The limiter is designed to buffer the load, allowing a surge period to pass before the current is limited. During the surge period, the inrush current is passed directly to the load, allowing for an accurate detection and rectification of the inrush current by the internal circuitry of the ICL.
The SL10 4R004-A ICL also includes a transient protection circuit, which monitors voltage to prevent any losses or surges in power. This circuit works by effectively diverting the power transients away from the power circuit, protecting from any damage or overload. It also provides an isolation buffer that ensures no high-grade energy is lost when the control circuit is in its disabled state.
Finally, SL10 4R004-A ICLs have built-in temperature protection that prevents the device from over-heating during long-term usage. The temperature protection features protect from device failure due to high temperatures, and can also activate a warning signal in the event of exceeding the temperature limit. This features ensures that the ICL operates consistently with optimal performance, even during harsh conditions.
SL10 4R004-A ICLs are ideal for a variety of applications requiring high-efficiency current limiting or circuit protection. With their advanced protection features, including temperature protection and transient protection, these ICLs make for a reliable and efficient control component in power systems.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
HLMP-SL10-HL0DD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LM0DD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LMKDD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LMLDD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LPKDD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-MNK00 | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-MNKDD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-MP0DD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-MQLDD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LP000 | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-LP0DD | Broadcom Lim... | 0.0 $ | 1000 | LED AMBER CLEAR 4MM OVAL ... |
HLMP-SL10-MNLDD | Broadcom Lim... | 0.0 $ | 1000 | HLMP-SL10-MNLDDLED Indica... |
SL1053B-NL | Littelfuse I... | 27.4 $ | 174 | HOLDER MOUNT FOR GAS TUBE... |
SL1011A075C | Littelfuse I... | 0.0 $ | 1000 | GDT 75V 5KAGas Discharge ... |
SL1011A145C | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 5KAGas Discharge... |
SL1011A400A | Littelfuse I... | 0.0 $ | 1000 | GDT 400V 5KA THROUGH HOLE... |
SL1011A400C | Littelfuse I... | 0.0 $ | 1000 | GDT 400V 5KAGas Discharge... |
SL1011B075A | Littelfuse I... | 0.0 $ | 1000 | GDT 75V 10KA THROUGH HOLE... |
SL1011B145A | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KA THROUGH HOL... |
SL1011B145C | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KAGas Discharg... |
SL1011B250C | Littelfuse I... | 0.0 $ | 1000 | GDT 250V 10KAGas Discharg... |
SL1021A090RS | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KA THROUGH HOL... |
SL1021A145C | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KAGas Discharg... |
SL1021A145R | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KA THROUGH HOL... |
SL1021A145RF | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KA T/H FAIL SH... |
SL1021A145RS | Littelfuse I... | 0.0 $ | 1000 | GDT 145V 10KA THROUGH HOL... |
SL1021A150C | Littelfuse I... | 0.0 $ | 1000 | GDT 150V 10KAGas Discharg... |
SL1021A150RF | Littelfuse I... | 0.0 $ | 1000 | GDT 150V 10KA T/H FAIL SH... |
SL1021A150RS | Littelfuse I... | 0.0 $ | 1000 | GDT 200V 10KA THROUGH HOL... |
SL1021A200RS | Littelfuse I... | 0.0 $ | 1000 | GDT 200V 10KA THROUGH HOL... |
SL1021A230RS | Littelfuse I... | 0.0 $ | 1000 | GDT 230V 10KA THROUGH HOL... |
SL1021A250RS | Littelfuse I... | 0.0 $ | 1000 | GDT 260V 10KA THROUGH HOL... |
SL1021A260RS | Littelfuse I... | 0.0 $ | 1000 | GDT 260V 10KA THROUGH HOL... |
SL1021A300RS | Littelfuse I... | 0.0 $ | 1000 | GDT 300V 10KA THROUGH HOL... |
SL1021A350RS | Littelfuse I... | 0.0 $ | 1000 | GDT 350V 10KA THROUGH HOL... |
SL1021A400RS | Littelfuse I... | 0.0 $ | 1000 | GDT 400V 10KA THROUGH HOL... |
SL1021A420RS | Littelfuse I... | 0.0 $ | 1000 | GDT 420V 10KA THROUGH HOL... |
SL1021A450RS | Littelfuse I... | 0.0 $ | 1000 | GDT 450V 10KA THROUGH HOL... |
SL1021A500RS | Littelfuse I... | 0.0 $ | 1000 | GDT 500V 10KA THROUGH HOL... |
SL1021A600RS | Littelfuse I... | 0.0 $ | 1000 | GDT 600V 10KA THROUGH HOL... |
ICL 1.3 OHM 25% 8A 13.97MMInrush Current...
ICL 10 OHM 20% 5A 12MMInrush Current Lim...
ICL 4 OHM 20% 23A 30MMInrush Current Lim...
ICL 16 OHM 20% 4A 22MMInrush Current Lim...
ICL 16 OHM 25% 4A 19.56MMInrush Current ...
ICL 33 OHM 20% 2.5A 15MMInrush Current L...