The LED display does not work, and the cause of the fault is determined and eliminated according to the flashing green light of the sending card.

Last Update Time: 2019-06-13 16:14:11


1. The display does not work, the sending card flashes green (for retractable)

 

(1) Cause of failure:

1) The screen is not powered;

2) The network cable is not connected well;

3) The receiving card has no power supply or the power supply voltage is too low;

4) The sending card is broken;

5) The signal transmission intermediate device is connected or has a fault (such as: function card, fiber transceiver box);

 

 (2) Troubleshooting method:

1) Check that the screen power supply is normal;

2) Check and reconnect the network cable;

3) Ensure that the power supply DC output is powered at 5-5.2V;

4) Replace the sending card;

5) Check the connection or replace the function card (fiber transceiver box);

 

2. The display does not work, the sending card does not flash green.

(1) Cause of failure:

1) The DVI or HDMI cable is not connected;

2) The copy or expansion mode in the graphics control panel is not set;

3) The software chooses to turn off the large screen power supply;

4) The sending card is not inserted or there is a problem with the sending card;

 

(2) Troubleshooting method:

1) Check the DVI line connector;

2) Reset the copy mode;

3) The software chooses to turn on the large screen power supply;

4) Re-insert the sending card or replace the sending card;

 

This article is from Allicdata Electronics Limited.