2026-07-C3 Allicdata Electronics
Allicdata Part #:

2026-07-C3-ND

Manufacturer Part#:

2026-07-C3

Price: $ 0.68
Product Category:

Circuit Protection

Manufacturer: Bourns Inc.
Short Description: GDT 75V 20% 20KA THROUGH HOLE
More Detail: Gas Discharge Tube 75V 20000A (20kA) ±20% 3 Pole T...
DataSheet: 2026-07-C3 datasheet2026-07-C3 Datasheet/PDF
Quantity: 1000
Lead Free Status / RoHS Status: Contains lead / RoHS non-compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
1000 +: $ 0.61945
Stock 1000Can Ship Immediately
$ 0.68
Specifications
Series: TRIGARD® 2026
Packaging: Tube 
Lead Free Status / RoHS Status: --
Part Status: Active
Moisture Sensitivity Level (MSL): --
Voltage - DC Spark Over (Nom): 75V
Impulse Discharge Current (8/20µs): 20000A (20kA)
Tolerance: ±20%
Number of Poles: 3
Fail Short: No
Mounting Type: Through Hole
Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Gas Discharge Tube Arresters (GDTs) are protective devices used in electrical circuits to protect sensitive electronic components from voltage spikes. They work on the principle that a small amount of electrical current, when allowed to pass through an ionized gas, will set off a miniature explosion. The resulting pressure wave will disperse the energy of the voltage spike and prevent damage to the circuit.

The GDT operates in its own designated voltage range and will only allow an electrical current in excess of this range to pass through. The process is initiated by the formation of a spark across the gap between the two electrodes. This spark serves to ionize the gas inside the tube and acts like a miniature electrical explosion. The ions produced in the explosion will then move along the outside of the tube, resulting in a pressure wave that disperses the energy of the voltage spike and prevents damage to the circuit.

The GDT has a wide variety of applications, such as in power transmission lines, industrial machines, motors, transformers, and more. GDTs are also used to protect telecommunications equipment from voltage surges. In addition, GDTs may be used for the protection of circuits used in automotive applications, as well as in the protection of automotive components.

GDTs can also be used in aircrafts and other vehicles for surge protection as they can help protect against damage from lightning strikes. GDTs are also used to protect sensitive equipment and high voltage electrical systems in buildings, and as part of personal safety systems. In military applications, GDTs can be used to protect sensitive systems from the effects of EMP (electromagnetic pulse) weapons.

GDTs are capable of protecting electrical equipment in a wide range of applications, from low-voltage to high-voltage. The characteristic that sets GDTs apart from other protectors is their fast response time, making them suitable for protecting against voltage surges and lightning strikes. Since GDTs are designed to disperse the energy of a voltage spike quickly and evenly, they can be used for a wide variety of applications from industrial settings to consumer applications.

GDTs must be carefully chosen for the application they are being used for. The most important factor to consider is the maximum voltage that the GDT can handle. GDTs are also available in different sizes and shapes, which can affect their performance, so careful selection of the appropriate GDT is important. Additionally, the design of the GDT must be suitable for the environment it is being used in, as some GDTs are designed specifically for indoor use while others are suited for outdoor use.

GDTs are an important part of any electrical system, and their use is becoming more widespread. GDTs have a wide variety of applications, from industrial to consumer use, and they can provide economical protection against voltage spikes and lightning strikes. However, they must be chosen carefully for the application they are being used for, and regular maintenance should be performed to ensure that they are functioning properly.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "2026" Included word is 40
Part Number Manufacturer Price Quantity Description
2026-35-C4 Bourns Inc. 1.51 $ 481 GDT 350V 20% 20KA THROUGH...
2026-60-C4LF Bourns Inc. 0.68 $ 1000 GDT 600V 20% 20KA THROUGH...
2026-35-C4FLF Bourns Inc. 0.88 $ 1000 GDT 350V 20% 20KA T/H FAI...
2026-42-C2FLF Bourns Inc. 0.88 $ 1000 GDT 420V 20% 20KA T/H FAI...
2026-20-C3FLF Bourns Inc. 0.88 $ 1000 GDT 200V 20% 20KA T/H FAI...
2026-09-ALF Bourns Inc. 0.61 $ 1000 GAS DISCHARGE TUBEGas Dis...
M39003/03-2026/HSD Vishay Sprag... 14.96 $ 1000 CAP TANT 220UF 20% 10V AX...
20265-ZZ TE Connectiv... 1.47 $ 1000 O RING
2026-07-CB Bourns Inc. 0.68 $ 1000 GDT 75V 20% 20KA THROUGH ...
M39003/09-2026/TR Vishay Sprag... 17.52 $ 1000 CAP TANT 68UF 10% 15V AXI...
2026-60-C4 Bourns Inc. 0.68 $ 1000 GDT 600V 20% 20KA THROUGH...
PEB 2026 T-S V1.1 Infineon Tec... 0.0 $ 1000 IC INTEG PWR CONTROLLER 2...
2026-60-CLF Bourns Inc. 0.64 $ 1000 GDT 600V 20% 20KA THROUGH...
2026-15-C18 Bourns Inc. 0.68 $ 1000 GDT 150V 20% 20KA THROUGH...
LED4-20265 Varitronix 8.73 $ 137 BACKLIGHT FOR TRANSFL GLA...
2026-07-C3 Bourns Inc. 0.68 $ 1000 GDT 75V 20% 20KA THROUGH ...
2026-26-C2 Bourns Inc. 0.68 $ 1000 GDT 260V 20% 20KA THROUGH...
2026-33-D5F Bourns Inc. 0.88 $ 1000 GDT 330V 20% 20KA T/H FAI...
2026-15-A1LF Bourns Inc. -- 1000 GDT 150V 20% 20KAGas Disc...
2026-07-C2 Bourns Inc. 1.51 $ 811 GDT 75V 20% 20KA THROUGH ...
2026-09-CLF Bourns Inc. 1.42 $ 321 GDT 90V 20% 20KA THROUGH ...
2026-23-CB Bourns Inc. 0.68 $ 1000 GDT 230V 20% 20KA THROUGH...
2026-07-CLF Bourns Inc. 0.64 $ 1000 GDT 75V 20% 20KA THROUGH ...
2026-23-CBLF Bourns Inc. 0.68 $ 1000 GDT 230V 20% 20KA THROUGH...
2026-23-A1FLF Bourns Inc. 0.88 $ 1000 GDT 230V 20% 20KA FAIL SH...
2026-09-C2FLF Bourns Inc. 0.88 $ 1000 GDT 90V 20% 20KA T/H FAIL...
202651-2 TE Connectiv... 19.25 $ 1000 SKT MODULE, 23 POSN, G-SE...
2026-26-C3LF Bourns Inc. 0.68 $ 1000 GDT 260V 20% 20KA THROUGH...
2026-09-C2LF Bourns Inc. 1.51 $ 2600 GDT 90V 20% 20KA THROUGH ...
2026-60-C8LF Bourns Inc. -- 1000 GDT 600V 20% 20KA THROUGH...
2026-47-C3FLF Bourns Inc. 0.88 $ 1000 GDT 470V 20% 20KA T/H FAI...
2026-07-A Bourns Inc. 0.61 $ 1000 GDT 75V 20% 20KAGas Disch...
MDLS-20265-LV-G Varitronix 0.0 $ 1000 LCD MODULE 20X2 SUPERTWIS...
2026-35-CLF Bourns Inc. 0.64 $ 1000 GDT 350V 20% 20KA THROUGH...
2026-25-C3FLF Bourns Inc. 0.88 $ 1000 GDT 250V 20% 20KA T/H FAI...
2026-42-C3FLF Bourns Inc. 0.88 $ 1000 GDT 420V 20% 20KA T/H FAI...
2026-30-C8 Bourns Inc. 0.68 $ 1000 GDT 300V 20% 20KA THROUGH...
2026-07-C3LF Bourns Inc. 0.68 $ 1000 GDT 75V 20% 20KA THROUGH ...
20267 Vicor Corpor... 28.57 $ 242 THERMMATE VI-J00 1=10PCS
2026-60-C8 Bourns Inc. 0.68 $ 1000 GDT 600V 20% 20KA THROUGH...
Latest Products
B88069X9960B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9960B102 Allicdata Electronics
B88069X9630C152

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9630C152 Allicdata Electronics
B88069X8591B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8591B102 Allicdata Electronics
B88069X8291S102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8291S102 Allicdata Electronics
B88069X7831B502

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X7831B502 Allicdata Electronics
B88069X5131B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X5131B102 Allicdata Electronics