| Allicdata Part #: | 2026-30-C2LF-ND |
| Manufacturer Part#: |
2026-30-C2LF |
| Price: | $ 0.68 |
| Product Category: | Circuit Protection |
| Manufacturer: | Bourns Inc. |
| Short Description: | GDT 300V 20% 20KA THROUGH HOLE |
| More Detail: | Gas Discharge Tube 300V 20000A (20kA) ±20% 3 Pole ... |
| DataSheet: | 2026-30-C2LF Datasheet/PDF |
| Quantity: | 1000 |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| 1000 +: | $ 0.61945 |
| Series: | TRIGARD® 2026 |
| Packaging: | Bulk |
| Lead Free Status / RoHS Status: | -- |
| Part Status: | Active |
| Moisture Sensitivity Level (MSL): | -- |
| Voltage - DC Spark Over (Nom): | 300V |
| Impulse Discharge Current (8/20µs): | 20000A (20kA) |
| Tolerance: | ±20% |
| Number of Poles: | 3 |
| Fail Short: | No |
| Mounting Type: | Through Hole |
| Package / Case: | Axial Cylinder, 3 Lead (Radial Bend) |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
2026-30-C2LF Application Field and Working Principle
Gas Discharge Tubes (GDT) also referred to as Gas Filled Arresters (GFA) have been used for the protection of electrical equipment from electrical surges. The 2026-30-C2LF is one type of the GDT that is specifically designed to protect and to limit over-voltages. It is very popular in many applications including automotive electronics, telecommunications, electronic control systems, and HVAC, among others. The main purpose of these tubes is to provide higher reliability during transient conditions when compared to other types of surge protectors.
The 2026-30-C2LF matches the needs of many electrical systems that require a high degree of reliability during transients as well as lower dynamic capacitance. It is especially ideal for applications that require high dynamic performance due to its ability to operate within tight response times. The 2026-30-C2LF can also be used in both single and double pole protection. It works by limiting how much current can pass through the arrester.
The 2026-30-C2LF is composed of three basic components: an anode and a cathode that are held together with a ceramic body. The ceramic body acts as the insulation between the anode and cathode. These components are then sealed with an epoxy, so that no electrons can escape and cause harm. The electrodes are designed to naturally form an arc, when the voltage between the anode and cathode exceeds its predetermined level. Once the current passes through the 2026-30-C2LF, it is discharged back to the power source in a safe manner. This supports improved system performance, because it protects against stress, impact, and any other electrical surges.
The 2026-30-C2LF works by two processes. The first process is called the “passive conduction process”. This is when a voltage is applied to the tube and a current flows from the anode to the cathode. This process is typically limited by the amount of current that is allowed to pass through the arrester before it reaches its predetermined voltage threshold, which is referred to as its “breakdown voltage”. The second process is called the “stimulated conducting process”. This process occurs when a higher potential is applied to the electrodes. This higher potential causes the anode and cathode to flip-flop, thus allowing more current to travel between the electrodes and providing more protection.
In addition to providing protection against excessive voltage and discharge protection, the 2026-30-C2LF also helps reduce the generation of harmonics. This is because it is designed to block higher frequency signals. This helps improve the efficiency of AC power sources as well as reduce the interference caused by these frequencies. Overall, the 2026-30-C2LF helps protect electrical systems from power surges and reduce harmful effects from high frequency interference.
The 2026-30-C2LF is a reliable and effective choice for many applications that require gas discharge tube arrester protection. Its design features provide excellent dynamic protection and allow it to respond quickly to transient conditions. It can also reduce the generation of harmonics, which leads to improved system efficiency. The 2026-30-C2LF is a highly recommended solution for many areas of technology.
The specific data is subject to PDF, and the above content is for reference
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| 2026-09-A1LF | Bourns Inc. | 0.62 $ | 1000 | GDT 90V 20% 20KAGas Disch... |
| 2026-26-C2F | Bourns Inc. | 0.88 $ | 1000 | GDT 260V 20% 20KA T/H FAI... |
| M39003/09-2026H | Vishay Sprag... | 21.56 $ | 1000 | CAP TANT 68UF 10% 15V AXI... |
| 2026-15-C2LF | Bourns Inc. | 1.51 $ | 5534 | GDT 150V 20% 20KA THROUGH... |
| 2026-40-C8 | Bourns Inc. | 0.68 $ | 1000 | GDT 400V 20% 20KA THROUGH... |
| 2026-60-CB | Bourns Inc. | 0.68 $ | 1000 | GDT 600V 20% 20KA THROUGH... |
| 2026-07-C4FLF | Bourns Inc. | 0.88 $ | 1000 | GDT 75V 20% 20KA T/H FAIL... |
| 2026-35-A1FLF | Bourns Inc. | 0.88 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
| 2026-35-C3LF | Bourns Inc. | 0.68 $ | 1000 | GDT 350V 20% 20KA THROUGH... |
| 2026-60-C3LF | Bourns Inc. | 0.68 $ | 1000 | GDT 600V 20% 20KA THROUGH... |
| 2026-25-A1FLF | Bourns Inc. | 0.88 $ | 1000 | GDT 250V 20% 20KA FAIL SH... |
| 2026-35-C3FLF | Bourns Inc. | 0.88 $ | 1000 | GDT 350V 20% 20KA T/H FAI... |
| 2026-07-C4F | Bourns Inc. | 0.88 $ | 1000 | GDT 75V 20% 20KA T/H FAIL... |
| 2026-47-C4LF | Bourns Inc. | -- | 1000 | GDT 470V 20% 20KA THROUGH... |
| 2026-35-C2 | Bourns Inc. | 0.68 $ | 1000 | GDT 350V 20% 20KA THROUGH... |
| 2026-23-C | Bourns Inc. | 0.64 $ | 1000 | GDT 230V 20% 20KA THROUGH... |
| 2026-47-C | Bourns Inc. | 0.64 $ | 1000 | GDT 470V 20% 20KA THROUGH... |
| VS-99-2026PBF | Vishay Semic... | 0.0 $ | 1000 | DIODE GENERAL PURPOSE TO2... |
| 2026H242A-9 | TE Connectiv... | 3.69 $ | 1000 | COAX CABLE-HIGH PERFOTwin... |
| 10069525-202609LF | Amphenol FCI | 3.21 $ | 1000 | CONN PLUG 200POS 0.8MM SM... |
| CHG-2026-J01010-KEP | 3M | 5.75 $ | 307 | CONN RECEPT IDC 26POS 24-... |
| M39003/03-2026 | Vishay Sprag... | 14.89 $ | 1000 | CAP TANT 220UF 20% 10V AX... |
| PEF 2026 T-S V1.1 | Infineon Tec... | 0.0 $ | 1000 | IC NETWORK TERMINATOR PDS... |
| 2026-07-C2 | Bourns Inc. | 1.51 $ | 811 | GDT 75V 20% 20KA THROUGH ... |
| 2026-09-CLF | Bourns Inc. | 1.42 $ | 321 | GDT 90V 20% 20KA THROUGH ... |
| 2026-15-CLF | Bourns Inc. | 0.64 $ | 1000 | GDT 150V 20% 20KA THROUGH... |
| 2026-47-C2F | Bourns Inc. | 0.88 $ | 1000 | GDT 470V 20% 20KA T/H FAI... |
| 2026-60-C4 | Bourns Inc. | 0.68 $ | 1000 | GDT 600V 20% 20KA THROUGH... |
| M39003/09-2026/TR | Vishay Sprag... | 17.52 $ | 1000 | CAP TANT 68UF 10% 15V AXI... |
| PEB 2026 T-S V1.1 | Infineon Tec... | 0.0 $ | 1000 | IC INTEG PWR CONTROLLER 2... |
| 2026-30-CB | Bourns Inc. | 0.68 $ | 1000 | GDT 300V 20% 20KA THROUGH... |
| 2026-42-C4 | Bourns Inc. | 0.68 $ | 1000 | GDT 420V 20% 20KA THROUGH... |
| VB10-2026 | Cinch Connec... | 1.52 $ | 1000 | CONN BNC PLUG STR 75OHM C... |
| 2026-35-C4 | Bourns Inc. | 1.51 $ | 481 | GDT 350V 20% 20KA THROUGH... |
| 2026-60-C4LF | Bourns Inc. | 0.68 $ | 1000 | GDT 600V 20% 20KA THROUGH... |
| 2026-35-C4FLF | Bourns Inc. | 0.88 $ | 1000 | GDT 350V 20% 20KA T/H FAI... |
| 2026-42-C2FLF | Bourns Inc. | 0.88 $ | 1000 | GDT 420V 20% 20KA T/H FAI... |
| 2026-40-CLF | Bourns Inc. | 0.64 $ | 1000 | GDT 400V 20% 20KA THROUGH... |
| 2026-07-C2F | Bourns Inc. | 0.88 $ | 1000 | GDT 75V 20% 20KA T/H FAIL... |
| 2026-42-C2F | Bourns Inc. | 0.88 $ | 1000 | GDT 420V 20% 20KA T/H FAI... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
2026-30-C2LF Datasheet/PDF