Allicdata Part #: | 495-76156-ND |
Manufacturer Part#: |
B88069X4900C103 |
Price: | $ 0.99 |
Product Category: | Circuit Protection |
Manufacturer: | EPCOS (TDK) |
Short Description: | GDT 230V 20% 10KA |
More Detail: | Gas Discharge Tube 230V 10000A (10kA) ±20% 2 Pole ... |
DataSheet: | ![]() |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 0.90720 |
5 +: | $ 0.87948 |
10 +: | $ 0.82215 |
50 +: | $ 0.68040 |
100 +: | $ 0.56700 |
250 +: | $ 0.55284 |
500 +: | $ 0.46778 |
1000 +: | $ 0.41108 |
5000 +: | $ 0.36855 |
Specifications
Series: | -- |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 230V |
Impulse Discharge Current (8/20µs): | 10000A (10kA) |
Tolerance: | ±20% |
Number of Poles: | 2 |
Fail Short: | No |
Mounting Type: | User Defined |
Package / Case: | Cylinder No Lead |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) – B88069X4900C103 application field and working principle
1. Introduction:
Gas Discharge Tubes (GDT) or direct current protective arresters are a type of electrical protection devices that are typically used to protect electric circuits from over voltage and over current transient phenomena. GDTs are often used in place of fuses and other forms of protection devices in order to limit the size of the current surge and consequently the voltage rise. The B88069X4900C103 is a type of GDT supplied by EPCOS, and is a form of surge arrester optimized for applications such as communication networks and in apparatus requiring safety class 1 or class 2 requirements. The B88069X4900C103 arrester characterizes itself by its robust design with enhanced characteristics against overvoltages, long lifetime and ease of operation due to its safe operation within the rated range even at high temperatures.2. Application Field and Working Principle:
The B88069X4900C103 GDT arrester is intended for installation over current and overvoltage protection needs over fixed broadband connection networks such as telecommunication networks and cable TV. These networks often require protection against both lightning strikes as well as against higher electrostatic charges that travel through cables in order to prevent damage to any equipment connected to the line. By connecting the GDT arrester at a suitable point on the line between the network and the device, it will limit any high energy transient that is being carried by the cables to a suitable level. Emphasis is placed on the arrester\'s capability to respond fast and without damages to inflammable material due to the insulation of the element. This is done through its internal design that, in the normal operation range, dissipates any transient permanently. When lightning or other high energy transients occur the arrester conducts it away to the line while blocking the energy and allowing only a simple and safe voltage to pass. This effectively shields the devices connected to the line.3. Technical Specifications:
The B88069X4900C103 GDT arrester is fully compliant with EN 61643-11 as well as VDE measures requirements and their characteristics ensure operation in any environment. This includes noise, severe electrical disturbances, overvoltages and lightning strikes. The B88069X4900C103 GDT arrester is also rated to handle up to 10KA current and up to 5kV voltage. The arrester is designed to be connected to lines of max 600V RMS AC, 400V DC, provided that its maximum ambient temperature of +70°C and the rated energy is not exceeded. The arrester is further equipped with a shell or enclosure which is fully UL 94V-0 approved.4. Conclusion:
The B88069x4900C103 GDT arrester is an effective and reliable form of protection for communication networks and devices. Its optimized design and characteristics make it easy to use and its robust shell and enclosure provide additional protection against overvoltages and transient phenomena. The B88069X4900C103 GDT arrester is an effective solution to protect against both lightning strikes as well as any electrostatic charges that may travel through cables. With these features it is a well suited arrester to protect a variety of communication networks and devices.The specific data is subject to PDF, and the above content is for reference
Related Products
Search Part number : "B880" Included word is 40
Part Number | Manufacturer | Price | Quantity | Description |
---|
B88069X9950B202 | EPCOS (TDK) | 0.0 $ | 1000 | SURGE ARRESTOR T67-C350XG... |
B88069X6071T203 | EPCOS (TDK) | -- | 16000 | GDT 150V 30% 2KA SURFACE ... |
B88069X4560T103 | EPCOS (TDK) | 0.61 $ | 1000 | GDT 570V 5KA THROUGH HOLE... |
B88069X5641T902 | EPCOS (TDK) | 0.29 $ | 1000 | GDT 1200V 15% SURFACE MOU... |
B88069X7240B502 | EPCOS (TDK) | 0.87 $ | 1000 | GDT 350V 20% 20KA T/H FAI... |
B88069X2890C102 | EPCOS (TDK) | 1.84 $ | 1000 | GAS DISCHARGE TUBE 8X20 6... |
B88069X8860B502 | EPCOS (TDK) | 0.87 $ | 1000 | GDT 250V 20% 20KA T/H FAI... |
B88069X4910C103 | EPCOS (TDK) | 0.99 $ | 4000 | GDT 350V 20% 10KAGas Disc... |
B88069X7320C502 | EPCOS (TDK) | 0.64 $ | 1000 | T20-A350XGas Discharge Tu... |
B88069X9260B502 | EPCOS (TDK) | 1.52 $ | 1000 | GDT 230V 10KA T/H FAIL SH... |
B88069X0240S102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X2683B502 | EPCOS (TDK) | 0.0 $ | 1000 | SURGE ARRESTOR TC33-C350X... |
B88069X5411T502 | EPCOS (TDK) | 0.41 $ | 1000 | EM 900XGas Discharge Tube... |
B88069X4970T352 | EPCOS (TDK) | 0.65 $ | 1000 | GDT 230V 20% 10KA SURFACE... |
B88069X7580B502 | EPCOS (TDK) | 0.81 $ | 1000 | GDT 350V 20KAGas Discharg... |
B88069X6980C203 | EPCOS (TDK) | 1.17 $ | 1000 | GDT 420V 20KAGas Discharg... |
B88069X9720B502 | EPCOS (TDK) | 1.52 $ | 1000 | GDT 230V 20% 10KA T/H FAI... |
B88069X2153B502 | EPCOS (TDK) | 0.0 $ | 1000 | SURGE ARRESTOR TC33-A230X... |
B88069X5151B502 | EPCOS (TDK) | 1.3 $ | 3058 | GDT 90V 20% 2.5KA THROUGH... |
B88069X3180C253 | EPCOS (TDK) | 0.48 $ | 1000 | GDT 350V 20% 10KAGas Disc... |
B88069X3831B502 | EPCOS (TDK) | 0.0 $ | 1000 | ER6-A230XGas Discharge Tu... |
B88069X5111B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 350V 20% 5KAGas Disch... |
B88069X7631B102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X8091B103 | EPCOS (TDK) | 0.35 $ | 1000 | 2 ELECT / 75VGas Discharg... |
B88069X1490T502 | EPCOS (TDK) | 0.69 $ | 1000 | GDT 500V 20% 20KA THROUGH... |
B88069X3930T103 | EPCOS (TDK) | 1.5 $ | 1000 | FS08X-1GBGas Discharge Tu... |
B88069X6700C253 | EPCOS (TDK) | 0.67 $ | 1000 | GDT 176V 5KAGas Discharge... |
B88069X5970S102 | EPCOS (TDK) | 0.96 $ | 2000 | GDT 145V 5KA 2 POLE THROU... |
B88069X7320C203 | EPCOS (TDK) | 1.51 $ | 2000 | GDT 350V 20% 20KAGas Disc... |
B88069X210S102 | EPCOS (TDK) | 2.08 $ | 394 | GDT 2000V THROUGH HOLEGas... |
B88069X8350B502 | EPCOS (TDK) | 1.58 $ | 500 | GDT 90V 10KA T/H FAIL SHO... |
B88069X1790C103 | EPCOS (TDK) | 0.96 $ | 448 | GDT 230V 15% 5KAGas Disch... |
B88069X4900C103 | EPCOS (TDK) | 0.99 $ | 1000 | GDT 230V 20% 10KAGas Disc... |
B88069X4990C103 | EPCOS (TDK) | 0.99 $ | 990 | GDT 600V 20% 10KAGas Disc... |
B88069X8690B502 | EPCOS (TDK) | 1.51 $ | 776 | GDT 350V 20% 10KA THROUGH... |
B88069X2710B502 | EPCOS (TDK) | 1.51 $ | 500 | GDT 260V 20% 10KA THROUGH... |
B88069X8070B502 | EPCOS (TDK) | 1.61 $ | 602 | GDT 350V 20KA THROUGH HOL... |
B88069X7990B502 | EPCOS (TDK) | 1.51 $ | 500 | GDT 300V 20% 10KA THROUGH... |
B88069X3820S102 | EPCOS (TDK) | 1.4 $ | 95 | GDT 1300V 15% 10KA THROUG... |
B88069X8840B502 | EPCOS (TDK) | 1.61 $ | 378 | GDT 250V 20% 20KA THROUGH... |
Latest Products
B88069X9960B102
GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9630C152
GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8591B102
GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8291S102
GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X7831B502
GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X5131B102
GAS DISCHARGE TUBEGas Discharge Tube ...