Allicdata Part #: | 495-76159-ND |
Manufacturer Part#: |
B88069X4990C103 |
Price: | $ 0.99 |
Product Category: | Circuit Protection |
Manufacturer: | EPCOS (TDK) |
Short Description: | GDT 600V 20% 10KA |
More Detail: | Gas Discharge Tube 600V 10000A (10kA) ±20% 2 Pole ... |
DataSheet: | ![]() |
Quantity: | 990 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 0.90720 |
5 +: | $ 0.87948 |
10 +: | $ 0.82215 |
50 +: | $ 0.68040 |
100 +: | $ 0.56700 |
250 +: | $ 0.55284 |
500 +: | $ 0.46778 |
1000 +: | $ 0.41108 |
5000 +: | $ 0.36855 |
Specifications
Series: | -- |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 600V |
Impulse Discharge Current (8/20µs): | 10000A (10kA) |
Tolerance: | ±20% |
Number of Poles: | 2 |
Fail Short: | No |
Mounting Type: | User Defined |
Package / Case: | Cylinder No Lead |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) are surge protection devices that are designed to protect electronic systems from damage caused by electrical surges. They are typically installed in power distribution lines, electrical wiring, and other electrical systems for protection against lightning strikes, power transients, and other overvoltage events. The B88069X4990C103 is an example of a GDT that provides excellent protection for digital circuits and other sensitive electronic systems. In this article, we will discuss the application field and working principle of the B88069X4990C103 Gas Discharge Tube Arrester.The B88069X4990C103 is a metal-oxide varistor (MOV)-type GDT. It is designed for use in telecom, switching and power electronics circuits, such as electronic gateways, data centers, base stations, and more. This GDT offers excellent protection for digital circuits, providing effective and reliable protection against 2- and 4-legged overvoltages that are caused by lightning strikes and power transients. Furthermore, it can be installed in coax cables and Ethernet cables to protect against ESD spikes and surges.The working principle behind the B88069X4990C103 GDT is based on a metal-oxide varistor (MOV) that functions as a voltage-sensitive resistor. When a surge in voltage or current is detected, the MOV is triggered and immediately begins to dissipate the extra voltage or current. This prevents the electronic system from being damaged by the surge. The MOV also has a limited lifetime and will eventually need to be replaced with a new one, but it is one of the most reliable surge protection components available and offers excellent protection for the system it is installed in.The B88069X4990C103 is also designed with an integrated thermal cut-off device. This device is designed to shut off power to the GDT when the temperature of the internal MOV component exceeds a certain threshold. This prevents the GDT from becoming damaged during prolonged periods of surge protection, ensuring its longevity. Additionally, the B88069X4990C103 is designed with capacitance and spark-gap technology that helps to prevent ESD surges from damaging the system.To install the B88069X4990C103, it must be connected to the power supply in series or parallel and connected to the protected equipment in parallel. This arrangement ensures that all the voltage and current is dissipated and that no surge protection is bypassed when the MOV is triggered. Additionally, it is important to install the B88069X4990C103 as close as possible to the protected equipment since the MOV’s reactivity time is decreased when it is further away from the equipment it is protecting.Overall, the B88069X4990C103 Gas Discharge Tube Arrester is an excellent surge protection device that offers excellent protection for digital circuits and other sensitive electronic systems. It is designed with a MOV, thermal cut-off device, capacitance technology, and spark-gap protection to provide reliable and effective protection against 2- and 4-legged overvoltages. Additionally, it must be installed as close as possible to the equipment it is protecting to ensure the best possible protection.The specific data is subject to PDF, and the above content is for reference
Related Products
Search Part number : "B880" Included word is 40
Part Number | Manufacturer | Price | Quantity | Description |
---|
B88069X9950B202 | EPCOS (TDK) | 0.0 $ | 1000 | SURGE ARRESTOR T67-C350XG... |
B88069X6071T203 | EPCOS (TDK) | -- | 16000 | GDT 150V 30% 2KA SURFACE ... |
B88069X4560T103 | EPCOS (TDK) | 0.61 $ | 1000 | GDT 570V 5KA THROUGH HOLE... |
B88069X5641T902 | EPCOS (TDK) | 0.29 $ | 1000 | GDT 1200V 15% SURFACE MOU... |
B88069X7240B502 | EPCOS (TDK) | 0.87 $ | 1000 | GDT 350V 20% 20KA T/H FAI... |
B88069X2890C102 | EPCOS (TDK) | 1.84 $ | 1000 | GAS DISCHARGE TUBE 8X20 6... |
B88069X8860B502 | EPCOS (TDK) | 0.87 $ | 1000 | GDT 250V 20% 20KA T/H FAI... |
B88069X4910C103 | EPCOS (TDK) | 0.99 $ | 4000 | GDT 350V 20% 10KAGas Disc... |
B88069X7320C502 | EPCOS (TDK) | 0.64 $ | 1000 | T20-A350XGas Discharge Tu... |
B88069X9260B502 | EPCOS (TDK) | 1.52 $ | 1000 | GDT 230V 10KA T/H FAIL SH... |
B88069X0240S102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X2683B502 | EPCOS (TDK) | 0.0 $ | 1000 | SURGE ARRESTOR TC33-C350X... |
B88069X5411T502 | EPCOS (TDK) | 0.41 $ | 1000 | EM 900XGas Discharge Tube... |
B88069X4970T352 | EPCOS (TDK) | 0.65 $ | 1000 | GDT 230V 20% 10KA SURFACE... |
B88069X7580B502 | EPCOS (TDK) | 0.81 $ | 1000 | GDT 350V 20KAGas Discharg... |
B88069X6980C203 | EPCOS (TDK) | 1.17 $ | 1000 | GDT 420V 20KAGas Discharg... |
B88069X9720B502 | EPCOS (TDK) | 1.52 $ | 1000 | GDT 230V 20% 10KA T/H FAI... |
B88069X2153B502 | EPCOS (TDK) | 0.0 $ | 1000 | SURGE ARRESTOR TC33-A230X... |
B88069X5151B502 | EPCOS (TDK) | 1.3 $ | 3058 | GDT 90V 20% 2.5KA THROUGH... |
B88069X3180C253 | EPCOS (TDK) | 0.48 $ | 1000 | GDT 350V 20% 10KAGas Disc... |
B88069X3831B502 | EPCOS (TDK) | 0.0 $ | 1000 | ER6-A230XGas Discharge Tu... |
B88069X5111B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 350V 20% 5KAGas Disch... |
B88069X7631B102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X8091B103 | EPCOS (TDK) | 0.35 $ | 1000 | 2 ELECT / 75VGas Discharg... |
B88069X1490T502 | EPCOS (TDK) | 0.69 $ | 1000 | GDT 500V 20% 20KA THROUGH... |
B88069X3930T103 | EPCOS (TDK) | 1.5 $ | 1000 | FS08X-1GBGas Discharge Tu... |
B88069X6700C253 | EPCOS (TDK) | 0.67 $ | 1000 | GDT 176V 5KAGas Discharge... |
B88069X5970S102 | EPCOS (TDK) | 0.96 $ | 2000 | GDT 145V 5KA 2 POLE THROU... |
B88069X7320C203 | EPCOS (TDK) | 1.51 $ | 2000 | GDT 350V 20% 20KAGas Disc... |
B88069X210S102 | EPCOS (TDK) | 2.08 $ | 394 | GDT 2000V THROUGH HOLEGas... |
B88069X8350B502 | EPCOS (TDK) | 1.58 $ | 500 | GDT 90V 10KA T/H FAIL SHO... |
B88069X1790C103 | EPCOS (TDK) | 0.96 $ | 448 | GDT 230V 15% 5KAGas Disch... |
B88069X4900C103 | EPCOS (TDK) | 0.99 $ | 1000 | GDT 230V 20% 10KAGas Disc... |
B88069X4990C103 | EPCOS (TDK) | 0.99 $ | 990 | GDT 600V 20% 10KAGas Disc... |
B88069X8690B502 | EPCOS (TDK) | 1.51 $ | 776 | GDT 350V 20% 10KA THROUGH... |
B88069X2710B502 | EPCOS (TDK) | 1.51 $ | 500 | GDT 260V 20% 10KA THROUGH... |
B88069X8070B502 | EPCOS (TDK) | 1.61 $ | 602 | GDT 350V 20KA THROUGH HOL... |
B88069X7990B502 | EPCOS (TDK) | 1.51 $ | 500 | GDT 300V 20% 10KA THROUGH... |
B88069X3820S102 | EPCOS (TDK) | 1.4 $ | 95 | GDT 1300V 15% 10KA THROUG... |
B88069X8840B502 | EPCOS (TDK) | 1.61 $ | 378 | GDT 250V 20% 20KA THROUGH... |
Latest Products
B88069X9960B102
GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9630C152
GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8591B102
GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8291S102
GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X7831B502
GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X5131B102
GAS DISCHARGE TUBEGas Discharge Tube ...