Allicdata Part #: | CG2300MS-ND |
Manufacturer Part#: |
CG2300MS |
Price: | $ 0.96 |
Product Category: | Circuit Protection |
Manufacturer: | Littelfuse Inc. |
Short Description: | GDT 300V 20KA SURFACE MOUNT |
More Detail: | Gas Discharge Tube 300V 20000A (20kA) 2 Pole Surf... |
DataSheet: | CG2300MS Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1000 +: | $ 0.87081 |
Series: | CG2 |
Packaging: | Tape & Reel (TR) |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 300V |
Impulse Discharge Current (8/20µs): | 20000A (20kA) |
Tolerance: | -- |
Number of Poles: | 2 |
Fail Short: | No |
Mounting Type: | Surface Mount |
Package / Case: | 2-SMD Cylinder Square End |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) are an integral part of power systems, providing an effective means of mitigating the destructive effects of lightning and other high-voltage electrical surges. The CG2300MS is a particularly durable and cost-effective arrester, suitable for a range of applications. This article will discuss the applications and working principles of the CG2300MS in detail.
Applications
The CG2300MS is a medium voltage (MV) arrester suitable for both indoor and outdoor installations. This makes it an ideal choice for power stations, substations, transmission and distribution systems, and other facilities, all of which require protection from high-voltage surges. Its compact design and wide range of mounting configurations make it suitable for a variety of applications, even in the most challenging environments.
The CG2300MS is a non-linear-suspension-type arrester, which gives the user the flexibility to configure the arrestor for various system protection schemes. This allows the user to tailor the arrester\'s response to different conditions, without needing to buy different types of arresters for different scenarios. Additionally, the arrester is designed for low-cost maintenance, with easily replaceable parts that can extend its life expectancy.
Working Principle
The CG2300MS is a gas-filled arrester, which works by limiting the flow of current directed towards the system it is protecting. In normal conditions, the arrester acts as an insulator, blocking the flow of current to protect the system from electrical surges. When electrical surges occur, the GDT will conduct the resulting surge current and dissipate it as heat, allowing the protected system to remain unharmed.
The device works by using the principle of current rectification (also known as the "avalanche effect"), which involves the flow of current through the GDT being utilised for its purpose. The electrical current is rectified by passing through a series of electrodes, converting the electrical current into low-level charge carriers which are then dissipated as heat.
The CG2300MS\'s robust design ensures that it is able to protect against lightning and other electrical surge currents up to 5,000 A. It is also able to sustain multiple surges of up to 10,000A and can withstand temperatures of up to 150 degrees Celsius. This ensures that the arrester is able to provide high-level protection to the system it is protecting.
Conclusion
The CG2300MS is a high-performance, cost-effective arrester that is suitable for a wide range of applications. Its ability to protect against high-voltage electrical surges, coupled with its low-cost maintenance requirements, make it an ideal solution for any system requiring surge protection. The CG2300MS\'s flexibility to configure its response to different conditions, as well as its robust design and ability to withstand extreme temperatures, make it one of the best arrester solutions on the market.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
CG232U035R2C | Cornell Dubi... | 7.74 $ | 1000 | CAP ALUM 2300UF 35V SCREW... |
CG2350 | Littelfuse I... | 0.92 $ | 1000 | GDT 350V 20KAGas Discharg... |
CG2350SN | Littelfuse I... | 0.92 $ | 1000 | GDT 350V 20KAGas Discharg... |
CG2300 | Littelfuse I... | 0.92 $ | 1000 | GDT 300V 20KAGas Discharg... |
CG2300MS | Littelfuse I... | 0.96 $ | 1000 | GDT 300V 20KA SURFACE MOU... |
CG2350LSNTR | Littelfuse I... | 0.97 $ | 1000 | GDT 350V 20KA THROUGH HOL... |
CG2350LSNTE | Littelfuse I... | 0.97 $ | 1000 | GDT 350V 20KA THROUGH HOL... |
CG2350LSTR | Littelfuse I... | 1.06 $ | 1000 | GDT 350V 20KA SURFACE MOU... |
CG2350LS | Littelfuse I... | 1.13 $ | 1000 | GDT 350V 20KA SURFACE MOU... |
CG2300LS | Littelfuse I... | 1.13 $ | 1000 | GDT 300V 20KA SURFACE MOU... |
CG2300LSTR | Littelfuse I... | 1.13 $ | 1000 | GDT 300V 20KA SURFACE MOU... |
CG2350LSN | Littelfuse I... | 1.27 $ | 1000 | GDT 350V 20KA THROUGH HOL... |
CG2300LSN | Littelfuse I... | 1.27 $ | 1000 | GDT 300V 20KA THROUGH HOL... |
CG2300L | Littelfuse I... | 1.27 $ | 1000 | GDT 300V 20KA THROUGH HOL... |
CG2350MS | Littelfuse I... | 1.08 $ | 1000 | GDT 350V 20KA SURFACE MOU... |
CG2300LSNTR | Littelfuse I... | 0.97 $ | 1000 | GDT 300V 20KA THROUGH HOL... |
CG2300LTR | Littelfuse I... | 0.97 $ | 1000 | GDT 300V 20KA THROUGH HOL... |
CG2350LTR | Littelfuse I... | 1.04 $ | 1000 | GDT 350V 20KA THROUGH HOL... |
CG2350L | Littelfuse I... | 2.12 $ | 1501 | GDT 350V 20KA THROUGH HOL... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...