Allicdata Part #: | CG2350LSNTR-ND |
Manufacturer Part#: |
CG2350LSNTR |
Price: | $ 0.97 |
Product Category: | Circuit Protection |
Manufacturer: | Littelfuse Inc. |
Short Description: | GDT 350V 20KA THROUGH HOLE |
More Detail: | Gas Discharge Tube 350V 20000A (20kA) 2 Pole Thro... |
DataSheet: | CG2350LSNTR Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1000 +: | $ 0.88376 |
Series: | CG2 |
Packaging: | Tape & Reel (TR) |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 350V |
Impulse Discharge Current (8/20µs): | 20000A (20kA) |
Tolerance: | -- |
Number of Poles: | 2 |
Fail Short: | No |
Mounting Type: | Through Hole |
Package / Case: | Axial Cylinder |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) are used to protect a variety of electrical systems, such as phone lines, data cables, and other electronic equipment, from electrical surges caused by lightning strikes and other electromagnetic events. The CG2350LSNTR is a type of GDT that is used to protect both AC and DC circuits, making it suitable for a wide range of applications. This article will discuss the application field and working principle of the CG2350LSNTR.
Application Field of the CG2350LSNTR
The CG2350LSNTR is a type of GDT intended mainly for use in outdoor power networks, telecommunications, and information technology systems. It is designed to protect both AC and DC circuits by limiting the maximum voltage of the system, shielding critical components from potential damage by electrical surged. The CG2350LSNTR is composed of two components, a conductor and a GDT. The conductor helps provide grounding, while the GDT shunts the electrical surge between the conductor and the protection device.
The CG2350LSNTR is ideal for use in applications that require a device to handle a wide range of electrical current surges, such as in medium voltage outdoor power networks and outdoor telecommunications. The device is resistant to both AC and DC voltages, making it suitable for protecting equipment installed in both common and industrial environments. The CG2350LSNTR has a wide range of applications, including transformer substations, circuit breakers, and even electronic consumer products such as computers and televisions.
Working Principle of the CG2350LSNTR
The CG2350LSNTR works by limiting the electrical surges that an AC or DC device is exposed to. This is done through the use of a GDT that is connected in series with the circuit. The GDT effectively shunts excess current away from the protected device, preventing it from experiencing potentially damaging surges. The CG2350LSNTR also helps provide an appropriate grounded conductor in order to prevent electrical arcing and ensure proper system performance.The CG2350LSNTR is equipped with a variety of technologies designed to protect electrical systems over a wide range of voltages. The most notable of these technologies is the Lightning Arrestor, which can detect incoming power surges and divert them away from the system. The device is also designed to resist high temperatures, making it suitable for use under extreme weather conditions.
In summary, the CG2350LSNTR is a type of GDT designed for outdoor power networks, telecommunications, and information technology systems. It works by limiting the voltage of the system, shielding components from potentially damaging electrical surges. The device is equipped with technologies such as the Lightning Arrestor, helping to protect systems under a wide range of conditions.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
CG232U035R2C | Cornell Dubi... | 7.74 $ | 1000 | CAP ALUM 2300UF 35V SCREW... |
CG2350 | Littelfuse I... | 0.92 $ | 1000 | GDT 350V 20KAGas Discharg... |
CG2350SN | Littelfuse I... | 0.92 $ | 1000 | GDT 350V 20KAGas Discharg... |
CG2300 | Littelfuse I... | 0.92 $ | 1000 | GDT 300V 20KAGas Discharg... |
CG2300MS | Littelfuse I... | 0.96 $ | 1000 | GDT 300V 20KA SURFACE MOU... |
CG2350LSNTR | Littelfuse I... | 0.97 $ | 1000 | GDT 350V 20KA THROUGH HOL... |
CG2350LSNTE | Littelfuse I... | 0.97 $ | 1000 | GDT 350V 20KA THROUGH HOL... |
CG2350LSTR | Littelfuse I... | 1.06 $ | 1000 | GDT 350V 20KA SURFACE MOU... |
CG2350LS | Littelfuse I... | 1.13 $ | 1000 | GDT 350V 20KA SURFACE MOU... |
CG2300LS | Littelfuse I... | 1.13 $ | 1000 | GDT 300V 20KA SURFACE MOU... |
CG2300LSTR | Littelfuse I... | 1.13 $ | 1000 | GDT 300V 20KA SURFACE MOU... |
CG2350LSN | Littelfuse I... | 1.27 $ | 1000 | GDT 350V 20KA THROUGH HOL... |
CG2300LSN | Littelfuse I... | 1.27 $ | 1000 | GDT 300V 20KA THROUGH HOL... |
CG2300L | Littelfuse I... | 1.27 $ | 1000 | GDT 300V 20KA THROUGH HOL... |
CG2350MS | Littelfuse I... | 1.08 $ | 1000 | GDT 350V 20KA SURFACE MOU... |
CG2300LSNTR | Littelfuse I... | 0.97 $ | 1000 | GDT 300V 20KA THROUGH HOL... |
CG2300LTR | Littelfuse I... | 0.97 $ | 1000 | GDT 300V 20KA THROUGH HOL... |
CG2350LTR | Littelfuse I... | 1.04 $ | 1000 | GDT 350V 20KA THROUGH HOL... |
CG2350L | Littelfuse I... | 2.12 $ | 1501 | GDT 350V 20KA THROUGH HOL... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...