Allicdata Part #: | T049032-ND |
Manufacturer Part#: |
T049032 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Bourns Inc. |
Short Description: | GAS DISCHARGE TUBE |
More Detail: | Gas Discharge Tube Pole |
DataSheet: | T049032 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | -- |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Moisture Sensitivity Level (MSL): | -- |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) are used in a wide variety of applications to protect against overvoltage and surge events. They are invaluable in providing the necessary protection for power systems, communication systems, electronic and instrumentation systems, and photoelectric detectors. In this article, we will learn about the application field and working principle of the T049032 GDT.
Application Field
The T049032 GDT is widely used in power systems, communication systems, and electronic and instrumentation systems due to its excellent performance and reliable protection. It can also be used in photoelectric detectors for protection against the highest surge voltages.
In power systems, the T049032 GDT acts as an overvoltage protector by providing the necessary breakdown voltage and current levels for protection against both normal and abnormal operating conditions. It can detect and suppress any surge or transient that result in disruptive or damaging effects. It also has a low impedance path to help ensure that power is not interrupted during surge events.
In communication systems, the T049032 GDT is used to provide protection against high voltage transients that can interfere with the transmission of data and other signals. It is used to suppress any transient signals that could cause disruption or data corruption.
In electronic and instrumentation systems, the T049032 GDT is used for protection against transient voltages, which can damage sensitive circuitry. It can be used to suppress electromagnetic interference (EMI) and reduce crosstalk between components.
Finally, in photoelectric detectors, the T049032 GDT is used to protect against the highest surge voltages that can be encountered in these applications. It can provide the necessary current and breakdown voltage levels to ensure the detector is not damaged by excessive voltage.
Working Principle
The T049032 GDT is a passive type of arrestor with a triggering voltage at or above which it turns on and is able to redirect a surge to ground. Upon the occurrence of an overvoltage event, the arrestor turns on and the overvoltage signal is shunted to ground, thus leading to its suppression. This operation is made possible by two components, a metal oxide varistor and a gas-filled chamber.
The metal oxide varistor is a components that is made up of a sintered material with two electrodes. When a high voltage is applied, the sintered material becomes conductive and results in a large decrease in the resistance. This allows a surge current to pass through the varistor and be dissipated.
The gas-filled chamber is an important component of the GDT since it is the one that turns on the arrestor. When a high voltage is applied, the air inside the chamber is ionized, resulting in an electrical arc. This arc is then able to conduct the high-voltage energy to ground, thus safely suppressing the surge.
The T049032 GDT is a reliable and cost effective device for protecting any system from overvoltage and surge events. Its wide range of applications and excellent performance makes it an indispensable part of any power, communication, electronic, or instrumentation system.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
T049001 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049012 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049015 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049016 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049018 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049032 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049056 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049058 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049076 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049078 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049099 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049118 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049147 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049166 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049167 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049187 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049217 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049238 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049245 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049248 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049358 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049368 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049399 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049481 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049739 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049796 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049246 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...