Allicdata Part #: | T049118-ND |
Manufacturer Part#: |
T049118 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Bourns Inc. |
Short Description: | GAS DISCHARGE TUBE |
More Detail: | Gas Discharge Tube Pole |
DataSheet: | T049118 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | -- |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Moisture Sensitivity Level (MSL): | -- |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) play a very important role in protecting electrical systems from lightning strikes, static electricity, and other forms of overvoltage. T049118 application field and working principle is a type of Gas Discharge Tube Arrestor which utilizes a nonlinear optical material such as quartz or silicon to create an optical effect when a high voltage is applied to it. The optical effect generated by the material causes a change in the voltage and current due to the presence of the material, allowing for a quick and safe protection against surges.
To understand how the GDT works, it is necessary to understand what gas is and how it works. Gas is a mixture of individual gaseous molecules that are collectively known as a gas. In a discharge tube, these molecules are energized by an electrical source which causes them to collide with one another creating a high-pressure environment. As the pressure increases, the molecules are forced to move faster, increasing the overall heat energy of the system. When an external voltage is applied to the discharge tube, the electrical source causes the molecules to become electrically charged and accelerate even further, resulting in an upward gain in energy.
In T049118 application field and working principle, the optical effect that occurs in the tube is utilized to create an artificial spark gap. This spark gap has a low-voltage threshold and a very high breakdown voltage. When the upswing of the voltage crosses the threshold of the spark gap, a spark is created, which allows the voltage and current to pass through quickly. This process occurs in nanoseconds, effectively protecting the system against spark gap damage.
The main advantages of using a GDT over other methods of surge protection are its lightning-quick response time and its low-voltage threshold. This lightning-quick response is due to the use of a nonlinear optical material which triggers the spark gap at low voltages, while the low-voltage threshold makes sure that only large surges are actually able to pass through the gap. This makes the GDT more reliable and reliable than other types of surge protection in terms of protecting against damages due to lightning and other surges. Furthermore, GDTs are highly durable and able to withstand extreme temperatures, making them an ideal choice for use in outdoor and industrial applications as well.
Overall, T049118 application field and working principle is a great tool for protecting against electrical surges. Gas Discharge Tube Arresters (GDT) are a reliable and effective form of surge protection due to their lightning-fast response time and their low-voltage threshold. GDTs are also highly durable, making them an ideal choice for outdoor or industrial applications. With their lightning-fast response time and reliable protection against high voltage surges, GDTs are the perfect choice for protecting your electrical system.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
T049001 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049012 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049015 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049016 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049018 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049032 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049056 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049058 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049076 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049078 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049099 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049118 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049147 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049166 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049167 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049187 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049217 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049238 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049245 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049248 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049358 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049368 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049399 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049481 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049739 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049796 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
T049246 | Bourns Inc. | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...