Allicdata Part #: | 974-1104-5-ND |
Manufacturer Part#: |
CQ2235 |
Price: | $ 0.00 |
Product Category: | Sensors, Transducers |
Manufacturer: | AKM Semiconductor Inc. |
Short Description: | SENSOR CURRENT HALL 50A AC/DC |
More Detail: | Current Sensor 85A 1 Channel Hall Effect, Open Loo... |
DataSheet: | CQ2235 Datasheet/PDF |
Quantity: | 1000 |
Frequency: | 300kHz |
Package / Case: | Module |
Mounting Type: | Through Hole |
Polarization: | Bidirectional |
Operating Temperature: | -40°C ~ 150°C |
Current - Supply (Max): | 9.6mA |
Response Time: | 1µs |
Voltage - Supply: | 2.7 V ~ 3.63 V |
Accuracy: | ±1% |
Linearity: | ±1% |
Series: | CQ |
Sensitivity: | 15.5mV/A |
Output: | Ratiometric, Voltage |
Number of Channels: | 1 |
Current - Sensing: | 85A |
Sensor Type: | Hall Effect, Open Loop |
For Measuring: | AC/DC |
Part Status: | Active |
Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Current transducers, such as the CQ2235, are a type of device used to measure, monitor, control and protect electrical circuits. It is a particularly useful device as it can be used to measure different types of currents, such as AC and DC. The CQ2235 is also known as a current transducer.
The CQ2235 is a highly accurate device designed to accurately measure, monitor and control the electrical current in a circuit. It is a single-input transducer which takes one current signal from the circuit and converts it into an output signal which is used to measure the current in the circuit. It is also able to measure various types of alternating and direct currents within a certain range.
The CQ2235 works by responding to a current signal in the circuit. When a current is sensed, the device produces an output signal which is proportional to the current measurement. This output signal can then be used to monitor and control the current in the circuit. The CQ2235 is also capable of producing an alarm signal if the current in the circuit exceeds a predetermined threshold value.
The CQ2235 is widely used in industrial applications for the measurement, monitoring and control of currents in AC and DC circuits. It is used to measure, monitor and protect circuits from overloads and other hazardous currents. Some common applications include:
- Monitoring loads and power distribution in manufacturing plants.
- Monitoring motor speed and torque in industrial machinery.
- Monitoring and controlling the current in industrial motors.
- Monitoring and controlling the current in pumps, fans, and other rotating machinery.
- Monitoring the charging of battery systems.
- Measuring the current in electronic circuits.
The CQ2235 is a highly efficient and reliable device which can be used to accurately measure and monitor the current in various AC and DC circuits. It is capable of providing accurate and reliable measurements in a wide range of applications, providing an ideal solution for the measurement, monitoring and control of currents in industrial environments.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
CQ220-10B | Central Semi... | 0.0 $ | 1000 | TRIAC 10A TO-220TRIAC Int... |
CQ220-10D | Central Semi... | 0.0 $ | 1000 | TRIAC 10A TO-220TRIAC Int... |
CQ220-10M | Central Semi... | 0.0 $ | 1000 | TRIAC 10A TO-220TRIAC Int... |
CQ220-10N | Central Semi... | 0.0 $ | 1000 | TRIAC 10A TO-220TRIAC Int... |
CQ220-12B | Central Semi... | 0.0 $ | 1000 | TRIAC 12A TO-220TRIAC Int... |
CQ220-12D | Central Semi... | 0.0 $ | 1000 | TRIAC 12A TO-220TRIAC Int... |
CQ220-12M | Central Semi... | 0.0 $ | 1000 | TRIAC 12A TO-220TRIAC Int... |
CQ220-12M SL | Central Semi... | 0.0 $ | 1000 | TRIAC 12A TO-220TRIAC Int... |
CQ220-12MFP | Central Semi... | 0.0 $ | 1000 | TRIAC 12A TO-220TRIAC Int... |
CQ220-12M3 SL | Central Semi... | 0.0 $ | 1000 | TRIAC 12A TO-220TRIAC Int... |
CQ220-12N | Central Semi... | 0.0 $ | 1000 | TRIAC 12A TO-220TRIAC Int... |
CQ220-16B | Central Semi... | 0.0 $ | 1000 | TRIAC 16A TO-220TRIAC Int... |
CQ220-16D | Central Semi... | 0.0 $ | 1000 | TRIAC 16A TO-220TRIAC Int... |
CQ220-16M | Central Semi... | -- | 1000 | TRIAC 16A TO-220TRIAC Int... |
CQ220-16M SL | Central Semi... | 0.0 $ | 1000 | TRIAC 16A TO-220TRIAC Int... |
CQ220-16MFP | Central Semi... | 0.0 $ | 1000 | TRIAC 16A TO-220TRIAC Int... |
CQ220-16N | Central Semi... | 0.0 $ | 1000 | TRIAC 16A TO-220TRIAC Int... |
CQ220-25B | Central Semi... | 0.0 $ | 1000 | TRIAC 25A TO-220TRIAC Int... |
CQ220-25D | Central Semi... | 0.0 $ | 1000 | TRIAC 25A TO-220TRIAC Int... |
CQ220-25M | Central Semi... | 0.0 $ | 1000 | TRIAC 25A TO-220TRIAC Int... |
CQ220-25MFP | Central Semi... | 0.0 $ | 1000 | TRIAC 25A TO-220TRIAC Int... |
CQ220-25N | Central Semi... | 0.0 $ | 1000 | TRIAC 25A TO-220TRIAC Int... |
CQ220-40M | Central Semi... | 0.0 $ | 1000 | TRIAC 40A TO-220TRIAC |
CQ220-40MFP | Central Semi... | 0.0 $ | 1000 | TRIAC 40A TO-220TRIAC |
CQ220-40N | Central Semi... | 0.0 $ | 1000 | TRIAC 40A TO-220TRIAC |
CQ220-40NFP | Central Semi... | 0.0 $ | 1000 | TRIAC 40A TO-220TRIAC |
CQ220-6BS | Central Semi... | 0.0 $ | 1000 | TRIAC 6A TO-220TRIAC Inte... |
CQ220-6D | Central Semi... | 0.0 $ | 1000 | TRIAC 6A TO-220TRIAC |
CQ220-6DS | Central Semi... | 0.0 $ | 1000 | TRIAC 6A TO-220TRIAC Inte... |
CQ220-6MS | Central Semi... | 0.0 $ | 1000 | TRIAC 6A TO-220TRIAC Inte... |
CQ220-6NS | Central Semi... | 0.0 $ | 1000 | TRIAC 6A TO-220TRIAC Inte... |
CQ220-8B | Central Semi... | 0.0 $ | 1000 | TRIAC 8A TO-220TRIAC Inte... |
CQ220-8B W/DC SL | Central Semi... | 0.0 $ | 1000 | TRIAC 8A TO-220TRIAC |
CQ220-8D | Central Semi... | 0.0 $ | 1000 | TRIAC 8A TO-220TRIAC Inte... |
CQ220-8DS | Central Semi... | 0.0 $ | 1000 | TRIAC 8A TO-220TRIAC |
CQ220-8M | Central Semi... | 0.0 $ | 1000 | TRIAC 8A TO-220TRIAC Inte... |
CQ220-8M3 SL | Central Semi... | 0.0 $ | 1000 | TRIAC 8A TO-220TRIAC Inte... |
CQ220-8MFP | Central Semi... | 0.0 $ | 1000 | TRIAC 8A TO-220TRIAC Inte... |
CQ220-8N | Central Semi... | 0.0 $ | 1000 | TRIAC 8A TO-220TRIAC Inte... |
CQ220-8NR | Central Semi... | 0.0 $ | 1000 | TRIAC 8A TO-220TRIAC Inte... |
SENSOR CURRENT XFMR 40A ACCurrent Sensor...
SENSOR CURRENT XFMR 5A ACCurrent Sensor ...
SENSOR CURRENT HALL 15A AC/DCCurrent Sen...
3 PIECE KIT SENSOR CURRENT HALLCurrent S...
PACT RCP-4000A-1A-D190Current Sensor 100...
SENSOR CURRENT HALL 30A DCCurrent Sensor...