2026-60-C8 Allicdata Electronics
Allicdata Part #:

2026-60-C8-ND

Manufacturer Part#:

2026-60-C8

Price: $ 0.68
Product Category:

Circuit Protection

Manufacturer: Bourns Inc.
Short Description: GDT 600V 20% 20KA THROUGH HOLE
More Detail: Gas Discharge Tube 600V 20000A (20kA) ±20% 3 Pole ...
DataSheet: 2026-60-C8 datasheet2026-60-C8 Datasheet/PDF
Quantity: 1000
Lead Free Status / RoHS Status: Contains lead / RoHS non-compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
1000 +: $ 0.61945
Stock 1000Can Ship Immediately
$ 0.68
Specifications
Series: TRIGARD® 2026
Packaging: Tube 
Lead Free Status / RoHS Status: --
Part Status: Active
Moisture Sensitivity Level (MSL): --
Voltage - DC Spark Over (Nom): 600V
Impulse Discharge Current (8/20µs): 20000A (20kA)
Tolerance: ±20%
Number of Poles: 3
Fail Short: No
Mounting Type: Through Hole
Package / Case: Cylinder 1 Lead, 3 Terminal
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Gas Discharge Tube (GDT) arresters are specialized devices used to provide immunity to high-voltage electrical-related disturbances for electrical substations and telecommunication systems. The 2026-60-C8 is an example of a commonly used GDT arrester. It is integrated with a wide range of other devices to provide surge protection and EMP shielding for numerous applications.

The 2026-60-C8 Gas Discharge Tube arrester works on the principle of high-voltage breakdown in an enclosed gas-filled chamber. During normal operation, the enclosed chamber is filled primarily with an inert gas, such as xenon, argon, or nitrogen. In the event of a surge or high-voltage interruption, the chamber’s gas rapidly ionizes and creates a conducting path between two electrodes. This conducting path disperses the energy related to the external disturbance and thereby shields the protected power system and equipment.

The 2026-60-C8 GDT arrester has a maximum peak current capacity of 600 Amps. It employs zinc oxide varistors with a voltage range of 10-60 kV. The arrester is designed to protect electrical systems and associated equipment from a wide range of short-duration electrical disturbances, including lightning, contact switching, and motor operation. The 2026-60-C8 is also designed to protect against long-duration electrical disturbances, such as over-voltage fluctuations and power loss.

The 2026-60-C8 GDT arrester is commonly used in various applications, including power distribution systems, telecommunications, and industrial automation. The arrester can be used to protect components such as transformers, motors, cables, and telecommunication systems from damage caused by surges. In addition, the arrester can be used to provide EMP shielding from high-voltage electromagnetic radiation.

In power distribution systems, GDT arresters are used to protect against power surges that may occur due to external disturbances, such as lightning strikes. The arresters are typically connected across the phase and neutral lines and are designed to quickly divert the current away from the electrical system, thereby preventing damage to electrical equipment. The 2026-60-C8 is specifically designed to handle the maximum peak load of 600 Amps.

In industrial automation, the 2026-60-C8 GDT arrester is used to protect motors, power supplies, and other sensitive components from voltage transients. The arrester is designed to quickly divert any excess voltage away from the system, preventing potential damage to the electrical components. Moreover, the arrester can be used to provide EMP shielding from high-voltage electromagnetic radiation.

In telecommunication systems, GDT arresters are used to protect telephone systems, data equipment, and other components from voltage transients. The 2026-60-C8 is designed to quickly divert any excess current away from the system, preventing any damage or interruptions to the communication. The arrester can also be used to protect against long-duration disturbances, such as over-voltage fluctuations and power loss.

In summary, the 2026-60-C8 GDT arrester is a commonly used device that provides immunity to a wide range of electrical-related disturbances. It is designed to quickly divert excess current away from a power system and associated equipment, thereby shielding them from potential damage. The arrester is used in a variety of applications, including power distribution systems, telecommunication systems, and industrial automation. In addition, the arrester can also be used to provide EMP shielding from high-voltage electromagnetic radiation.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "2026" Included word is 40
Part Number Manufacturer Price Quantity Description
2026-35-C4 Bourns Inc. 1.51 $ 481 GDT 350V 20% 20KA THROUGH...
2026-60-C4LF Bourns Inc. 0.68 $ 1000 GDT 600V 20% 20KA THROUGH...
2026-35-C4FLF Bourns Inc. 0.88 $ 1000 GDT 350V 20% 20KA T/H FAI...
2026-42-C2FLF Bourns Inc. 0.88 $ 1000 GDT 420V 20% 20KA T/H FAI...
2026-20-C3FLF Bourns Inc. 0.88 $ 1000 GDT 200V 20% 20KA T/H FAI...
2026-09-ALF Bourns Inc. 0.61 $ 1000 GAS DISCHARGE TUBEGas Dis...
M39003/03-2026/HSD Vishay Sprag... 14.96 $ 1000 CAP TANT 220UF 20% 10V AX...
20265-ZZ TE Connectiv... 1.47 $ 1000 O RING
2026-07-CB Bourns Inc. 0.68 $ 1000 GDT 75V 20% 20KA THROUGH ...
M39003/09-2026/TR Vishay Sprag... 17.52 $ 1000 CAP TANT 68UF 10% 15V AXI...
2026-60-C4 Bourns Inc. 0.68 $ 1000 GDT 600V 20% 20KA THROUGH...
PEB 2026 T-S V1.1 Infineon Tec... 0.0 $ 1000 IC INTEG PWR CONTROLLER 2...
2026-60-CLF Bourns Inc. 0.64 $ 1000 GDT 600V 20% 20KA THROUGH...
2026-15-C18 Bourns Inc. 0.68 $ 1000 GDT 150V 20% 20KA THROUGH...
LED4-20265 Varitronix 8.73 $ 137 BACKLIGHT FOR TRANSFL GLA...
2026-07-C3 Bourns Inc. 0.68 $ 1000 GDT 75V 20% 20KA THROUGH ...
2026-26-C2 Bourns Inc. 0.68 $ 1000 GDT 260V 20% 20KA THROUGH...
2026-33-D5F Bourns Inc. 0.88 $ 1000 GDT 330V 20% 20KA T/H FAI...
2026-15-A1LF Bourns Inc. -- 1000 GDT 150V 20% 20KAGas Disc...
2026-07-C2 Bourns Inc. 1.51 $ 811 GDT 75V 20% 20KA THROUGH ...
2026-09-CLF Bourns Inc. 1.42 $ 321 GDT 90V 20% 20KA THROUGH ...
2026-23-CB Bourns Inc. 0.68 $ 1000 GDT 230V 20% 20KA THROUGH...
2026-07-CLF Bourns Inc. 0.64 $ 1000 GDT 75V 20% 20KA THROUGH ...
2026-23-CBLF Bourns Inc. 0.68 $ 1000 GDT 230V 20% 20KA THROUGH...
2026-23-A1FLF Bourns Inc. 0.88 $ 1000 GDT 230V 20% 20KA FAIL SH...
2026-09-C2FLF Bourns Inc. 0.88 $ 1000 GDT 90V 20% 20KA T/H FAIL...
202651-2 TE Connectiv... 19.25 $ 1000 SKT MODULE, 23 POSN, G-SE...
2026-26-C3LF Bourns Inc. 0.68 $ 1000 GDT 260V 20% 20KA THROUGH...
2026-09-C2LF Bourns Inc. 1.51 $ 2600 GDT 90V 20% 20KA THROUGH ...
2026-60-C8LF Bourns Inc. -- 1000 GDT 600V 20% 20KA THROUGH...
2026-47-C3FLF Bourns Inc. 0.88 $ 1000 GDT 470V 20% 20KA T/H FAI...
2026-07-A Bourns Inc. 0.61 $ 1000 GDT 75V 20% 20KAGas Disch...
MDLS-20265-LV-G Varitronix 0.0 $ 1000 LCD MODULE 20X2 SUPERTWIS...
2026-35-CLF Bourns Inc. 0.64 $ 1000 GDT 350V 20% 20KA THROUGH...
2026-25-C3FLF Bourns Inc. 0.88 $ 1000 GDT 250V 20% 20KA T/H FAI...
2026-42-C3FLF Bourns Inc. 0.88 $ 1000 GDT 420V 20% 20KA T/H FAI...
2026-30-C8 Bourns Inc. 0.68 $ 1000 GDT 300V 20% 20KA THROUGH...
2026-07-C3LF Bourns Inc. 0.68 $ 1000 GDT 75V 20% 20KA THROUGH ...
20267 Vicor Corpor... 28.57 $ 242 THERMMATE VI-J00 1=10PCS
2026-60-C8 Bourns Inc. 0.68 $ 1000 GDT 600V 20% 20KA THROUGH...
Latest Products
B88069X9960B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9960B102 Allicdata Electronics
B88069X9630C152

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9630C152 Allicdata Electronics
B88069X8591B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8591B102 Allicdata Electronics
B88069X8291S102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8291S102 Allicdata Electronics
B88069X7831B502

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X7831B502 Allicdata Electronics
B88069X5131B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X5131B102 Allicdata Electronics