2027-25-A Allicdata Electronics
Allicdata Part #:

2027-25-A-ND

Manufacturer Part#:

2027-25-A

Price: $ 0.42
Product Category:

Circuit Protection

Manufacturer: Bourns Inc.
Short Description: GDT 250V 15% 10KA
More Detail: Gas Discharge Tube 250V 10000A (10kA) ±15% 2 Pole ...
DataSheet: 2027-25-A datasheet2027-25-A Datasheet/PDF
Quantity: 1000
Lead Free Status / RoHS Status: Contains lead / RoHS non-compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
1000 +: $ 0.38367
Stock 1000Can Ship Immediately
$ 0.42
Specifications
Series: 2027
Packaging: Bulk 
Lead Free Status / RoHS Status: --
Part Status: Active
Moisture Sensitivity Level (MSL): --
Voltage - DC Spark Over (Nom): 250V
Impulse Discharge Current (8/20µs): 10000A (10kA)
Tolerance: ±15%
Number of Poles: 2
Fail Short: No
Mounting Type: User Defined
Package / Case: Cylinder No Lead
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Gas Discharge Tube Arresters (GDT) are used to prevent electrical equipment from being damaged or destroyed by high voltage electrical discharges, such as lightning strikes. They act as a protective barrier between the equipment and the outside environment, absorbing and safely dissipating the energy of the high voltage surge. The 2027-25-A application field and working principle is a critical component of GDTs and will be discussed in detail in this article.

Description

The 2027-25-A GDT is made up of a metal shell, a metallic arrester core, a ceramic insulating liner, and a spark gap assembly. The metal shell provides mechanical protection and serves as an electrical return path for the discharge current. The metallic arrester core is a conductive material such as copper, brass, or aluminum and functions to provide electrical conduction in the event of a high-voltage surge. The ceramic insulator is used to block the electrical conduction between the arrester core and the outer metal shell. Finally, the spark gap assembly is made up of a series of metal electrodes which form an electrical gap between the arrester core and the outer shell. The gap is set to a specific width established by the parameters of the GDT, and when a high-voltage surge is detected, a spark will bridge the gap and the arrester core will conduct the current and dissipate the energy from the surge.

Principle Of Operation

The 2027-25-A GDT works on the principle that it can absorb and safely dissipate the energy of high-voltage surges while providing a safe level of electrical conduction. When a high-voltage surge is detected, the electrodes in the spark gap assembly detect the surge and bridge the gap. This causes the arrester core to become conductive and allows the energy of the surge to be discharged safely to the ground. The surge current then flows through the arrester core and is safely dissipated by the ceramic insulator. This process occurs quickly, and the arrester core is designed to remain conductive only for a short period of time.

Application Field

The 2027-25-A GDT is designed for use in applications where it is important to protect sensitive electrical equipment from the effects of high-voltage surges such as lightning strikes. It is suitable for use with both AC and DC circuits, and is often used in residential, commercial, and industrial facilities where protection against high-voltage surges is desired. It is also used in communication equipment, military installations, medical facilities, and other sensitive electronic applications.

Advantages Of 2027-25-A GDT

The 2027-25-A GDT offers several advantages over other surge protection devices. These include:

  • It is easy to install and requires no additional components or tools.
  • It is highly resistant to lightning strikes and electrical surges.
  • It offers excellent protection against overvoltage.
  • It can be used with both AC and DC circuits.
  • It is designed to quickly and safely dissipate electrical surges.
  • It is capable of protecting sensitive electrical equipment from damage.

The 2027-25-A GDT is a reliable and affordable solution for protecting electrical equipment from high-voltage surges. Its simple design and easy installation make it an ideal choice for residential, commercial, and industrial applications.

Conclusion

The 2027-25-A GDT is a reliable and effective surge protection device that is designed to protect sensitive electrical equipment from damage due to high-voltage surges. It works on the principle of absorbing and dissipating the energy of the surge before it can reach the equipment. It is easy to install and requires no additional components or tools. Its simple design and reliable performance make it an ideal choice for a range of applications, including residential, commercial, and industrial facilities.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "2027" Included word is 39
Part Number Manufacturer Price Quantity Description
2027-47-SM-RPLF Bourns Inc. 0.44 $ 500 GDT 470V 15% 10KA SURFACE...
2027-25-B10 Bourns Inc. 0.44 $ 1000 GDT 250V 15% 10KA THROUGH...
2027-40-CLF Bourns Inc. 0.44 $ 1000 GDT 400V 15% 10KA THROUGH...
0113-201-2027 TE Connectiv... 0.89 $ 1000 O-RING
2027-23-ALF Bourns Inc. 0.42 $ 1000 GDT 230V 15% 10KAGas Disc...
2027-09-BLF Bourns Inc. 0.98 $ 653 GDT 90V 20% 10KA THROUGH ...
2027-35-SMLF Bourns Inc. 0.37 $ 1000 GDT 350V 15% 10KA SURFACE...
2027-35-B Bourns Inc. 0.44 $ 1000 GDT 350V 15% 10KA THROUGH...
202713-1 TE Connectiv... 70.97 $ 102 CONN SHIELD 75POS 2PC SHO...
2027-25-C10LF Bourns Inc. 0.44 $ 1000 GDT 250V 15% 10KA THROUGH...
2027-42-BLF Bourns Inc. 0.98 $ 531 GDT 420V 15% 10KA THROUGH...
2027-23-CLF Bourns Inc. 0.98 $ 998 GDT 230V 15% 10KA THROUGH...
2027-07-SMLF Bourns Inc. 0.82 $ 541 GDT 75V 20% 10KA SURFACE ...
2027-09-CLF Bourns Inc. 0.98 $ 948 GDT 90V 20% 10KA THROUGH ...
2027-25-BLF Bourns Inc. 0.98 $ 477 GDT 250V 15% 10KA THROUGH...
2027-47-CLF Bourns Inc. -- 337 GDT 470V 15% 10KA THROUGH...
2027-30-C10 Bourns Inc. 0.44 $ 1000 GDT 300V 15% 10KA THROUGH...
202795-4 TE Connectiv... 61.17 $ 1000 PLUG KIT 3 MODULE G-SERIE...
2027-35-CLF Bourns Inc. 0.44 $ 1000 GDT 350V 15% 10KA THROUGH...
2027-30-SM Bourns Inc. 0.37 $ 1000 GDT 300V 15% 10KA SURFACE...
2027-09-SMLF Bourns Inc. 0.82 $ 1938 GDT 90V 20% 10KA SURFACE ...
2027-40-C Bourns Inc. 0.44 $ 1000 GDT 400V 15% 10KA THROUGH...
2027-40-C10LF Bourns Inc. 0.44 $ 1000 GDT 400V 15% 10KA THROUGH...
2027-25-BT1 Bourns Inc. 0.48 $ 1000 GDT 250V 15% 10KA THROUGH...
202726-1 TE Connectiv... 7.28 $ 1000 CONN SOCKET (2)18AWG GOLD...
2027-09-C10 Bourns Inc. 0.44 $ 1000 GDT 90V 20% 10KA THROUGH ...
CCM01-2027LFT T30 C&K 3.83 $ 1945 CONN SMART CARD PUSH-PULL...
2027-23-BLF Bourns Inc. 0.98 $ 1000 GDT 230V 15% 10KA THROUGH...
2027-42-SMLF Bourns Inc. 0.37 $ 1000 GDT 420V 15% 10KA SURFACE...
202711-3 TE Connectiv... 0.0 $ 1000 CONN SHIELD 75POS 2PC LON...
2027-15-BT1 Bourns Inc. 0.48 $ 1000 GDT 150V 15% 10KA THROUGH...
M39003/03-2027 Vishay Sprag... 15.64 $ 1000 CAP TANT 270UF 10% 10V AX...
19-09-2027 Molex Connec... 0.44 $ 3740 CONN PLUG 2POS .093 PANEL...
2027-35-SM Bourns Inc. 0.37 $ 1000 GDT 350V 15% 10KA SURFACE...
2027-47-C10LF Bourns Inc. 0.44 $ 1000 GDT 470V 15% 10KA THROUGH...
2027-23-A Bourns Inc. 0.42 $ 1000 GDT 230V 15% 10KAGas Disc...
2027-47-C Bourns Inc. 0.44 $ 1000 GDT 470V 15% 10KA THROUGH...
2027-60-C Bourns Inc. 0.44 $ 1000 GDT 600V 15% 10KA THROUGH...
UPL1-2027-4 Sensata-Airp... 0.0 $ 1000 CIRCUIT BREAKER MAG-HYDR ...
Latest Products
B88069X9960B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9960B102 Allicdata Electronics
B88069X9630C152

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9630C152 Allicdata Electronics
B88069X8591B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8591B102 Allicdata Electronics
B88069X8291S102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8291S102 Allicdata Electronics
B88069X7831B502

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X7831B502 Allicdata Electronics
B88069X5131B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X5131B102 Allicdata Electronics